Repair step

  • The last section of riser main pipe will have the pump cylinder attached to the bottom.
  • Pull the assembly of riser main pipe and cylinder out of the well and set the assembly on a block of wood to keep the cylinder off the ground.
Step 2

Repair step

  • Using two pipe wrenches, unscrew the cylinder from the riser main.
Step 3

Repair step

  • Slowly pull the cylinder off of the pump rod, exposing the traveling valve and foot valve.