FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

How to fix the main motor of Petcube Bites 2 Lite

This guide actually covers the Petcube Bites 2...

iFixit Library Petcube Bites Easy 15 - 20 minutes Guide 161990
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

This guide actually covers the Petcube Bites 2 Lite, but I'm assuming all their cameras are similar internally. Mine had stop giving treats because the mine motor had stopped spinning. Since my device was out of warranty, Petcube support didn't have other options than purchasing another device. I didn't have anything to lose at this point to try to repair it myself, which ended up being not really hard, and is shown in this guide.

Step 1

Prepare for disassembly

  • Start by pressing the 2 clips on each side of the device to remove the tread holder head.
  • Once inside, pry out the size insert and the treat motor cap.
Step 2

Remove the treat holder

  • Unscrew the 2 larger Philips screws to be able to remove the base of the treat holder from the device body.
Step 3

Get inside the device body

  • The core device can actually be accessed by the bottom; screws are hidden under the rubber pad.
  • The rubber pad is simply glued to the bottom, you can easily unstick it from the shell to gain access to the screws.
  • Be careful to only pull the rubber part and not the entire bottom. I initially tried to force it out and figured out the screw location by breaking it... don't do that.
  • Under the rubber pads are 4 Philips screws to get inside.
Step 4

Remove the physical controls

  • Once inside, you'll find a board that hosts the physical controls of the device.
  • Remove the 2 Philips screw to remove it from its place.
  • Then disconnect the ribbon cable and put the board away.
Step 5

Open the device core

  • Once the controls are removed, you can simply slide the core of the device out of its shell.
  • You'll find 3 Philips screws (2 on the left, 1 on the right) to get inside the core.
Step 6

Remove the motor

  • The 3 Philips screws holding the motor to the structure can be removed.
  • The motor won't slide out immediately – you'll also need to remove the encoder sensor. Just pull it out carefully from its socket.
  • While trying to slide the motor out, make sure to disconnect its cable from the main board.
  • The motor can then be disassembled by removing the 2 Philips screw holding its shell.
Step 7

Fix the motor

  • Inside the motor, just realign all the cogs together so that everything spins together.
Step 8

Test the motor (optional)

  • If you want to test out the motor before reassembling everything:
  • Reconnect all the cables that were disconnected during disassembly
  • Plug the device back in
  • Connect to the device through the Petcube app, and try flinging a treat
  • The motor will instantly respond (or not) and make it easier to find what's wrong, or if the motor needs replacement.