Air Fryer Princess 182024 – Does not turn on, failure of the input power thermal fuse.

Attributed iFixit repair guide for Freidora de aire - Princess 182024.

iFixit Library Freidora de aire - Princess 182024 Moderate 2 hours Guide 162215
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Step 1

Repair step

  • Hot‑air work carried out during the Repair Café Palma on June 14, 2023. The photos were taken on the fly with the collaboration of the volunteers, so I’m sorry that some images lack definition and that the step‑by‑step process is not as complete as I usually prepare in other documents.
  • FAULT: The fryer does not heat up, nor does the fan run; only the display turns on.
  • ISSUE DETECTED AND RESOLVED: The thermal fuse was located (it has two units) and replaced.
  • From what I’ve been able to research on this topic, this is a very common failure in hot‑air fryers.
  • Step 1: Remove the top cover. It is clipped in place, so it must be taken off using a spatula or a flat‑type pry tool.
Step 2

Repair step

  • Removing the screws under the top cover, we free the upper housing. Be careful: it remains connected to the display’s flex cable, its two connectors must be disconnected. Recommend, ALWAYS mark their orientation even if it seems simple and obvious, it helps during reassembly as shown on the white connector on the right side in photo 2.
  • Photo 2: Blue and red wires on the right side, ACN (Neutral) and ACL (Line) power input. NOTE: These FASTON connectors have a central safety clip that prevents them from coming loose; if you don’t press it, the FASTON cannot be removed.
  • The red wire, ACL (AC input, Phase), is connected to the input of the black relay on the left side. Through this relay, it supplies the blue wire on the left side (HOT – heating element) and the black wire (fan).
  • We observed that by directly bridging the RED and LEFT BLUE wires, the heating element did not warm up and the fan did not activate. Measuring directly at the heating element showed that no voltage was reaching it. THIS LED TO THE SUSPICION THAT THERE WAS A HIDDEN THERMAL FUSE.
Step 3

Repair step

  • PHOTO 1: Since we were unfamiliar with the machine, we had to investigate and learn on the fly. We unscrewed the screw and nut of the thermal probe; it is not necessary to remove it, so it was re‑secured.
  • Note: To access the thermal fuses located underneath, you must first loosen the nut of the fan’s impeller. The aluminum impeller bends easily, so when reassembling it will need to be readjusted because it will rub.
  • PHOTO 2: All screws from the lid support must be removed in order to access the two thermal fuses located underneath. They are secured with the same screw that fastens the heating element to the metal chassis. This screw uses a nut, so if you cannot insert pliers or your fingers underneath, the nut will spin freely and cannot be unscrewed.
Step 4

Repair step

  • THIS STEP IS NOT NECESSARY TO ACCESS THE thermal fuses, but as I indicated before, since we had to learn as we went along and DID NOT HAVE DOCUMENTATION, we mistakenly disassembled the motor because it wouldn't start. AS A CURIOSITY: We located the hidden thermal fuse by separating the winding casing.
  • The motor measures approximately 289 ohms; our reading had been falsified, indicating INFINITY, OPEN CIRCUIT, because we were measuring on a very low scale on the multimeter, mistakenly measuring on the 200-ohm scale. (We were not using an AUTOSCALE multimeter; when using a fixed-scale one, you must test on several scales of the device).
  • We proceeded to change to a higher scale and the measurement was correct, so the motor is OK. It helped us discover the thermal fuse that the motor has hidden in its winding and verify that it is ok, so at least it served as a learning experience for a future repair. We reassembled the motor.
Step 5

Repair step

  • Photo 1: After removing a lot of screws, including the motor propeller nut, we managed to access the underside of the metal base, where you can barely see the 2 thermal fuses from one side. In the photo, they are already shown loose from the screw that fixes them to the base.
  • Photo 2: We checked both thermal fuses with a multimeter on the ohms scale and observed that one of them is OPEN, IT DOES NOT GIVE CONTINUITY = BURNT OUT.
  • Photo 3: We proceeded to replace the thermal fuse, securing the replacement with 2 terminal blocks. I have already thought about how to improve this, so I will dedicate another document to how to replace thermal fuses by crimping the replacement. I will include the link to that document here as soon as I have it ready.
  • ORIGINAL THERMAL FUSE VALUE: 172ºC / 10 A / 250V
  • Any with the same value or slightly higher and the same amperage or higher will work.
Step 6

Repair step

  • View of the original thermal fuse partially disassembled and view of the replacement thermal fuse. Once secured with terminal blocks, we can cover it with its original sleeve if it fits, or otherwise apply heat shrink tubing.
  • We can see in photo 1 that the cooling fan consists of a double propeller: an inner side and the one next to the resistance, the outer side.
Step 7

Repair step

  • Thermal fuse value, AUPO BF172 172° / 10 A / 250V -G1. Measured with a multimeter on the ohms scale (continuity scale, or the lowest ohms scale). If it is faulty, blown, it will show an open circuit, "measures nothing".
  • Be sure to check both fuses, although usually only one of the two blows, the one closest to the metal plate.
Step 8

Repair step

  • Once the blown thermal fuse has been replaced, reassemble the entire unit in reverse order.
  • Photo 2: You can see the tray detection switch at the bottom center; for safety reasons, the machine will not work if this is not activated.
  • Photo 3: Base assembly,
Step 9

Repair step

  • Machine working.
  • SUMMARY: THE MAIN PROBLEM IN HOT AIR FRYERS THAT DO NOT HEAT UP IS THE OPENING OF THE PROTECTIVE thermal fuse, located on the metal sheet support of the resistance.
  • PRINCESS HOT AIR FRYER: Thermal fuse value, AUPO BF172 172° / 10 A / 250V -G1 is located on the metal sheet of the resistance, it involves disassembling almost the entire machine, it has 2 fuses covered in textile tube, one of them usually blows, it implies that it does not heat up and the cooling fan does not turn, the screen does turn on.
  • COMPLEMENTARY DOCUMENT: Other thermal fuses in household appliances. https://es.ifixit.com/Gu%C3%ADa/VALORES+...