Step 1

Which razors does this manual apply to?

  • This manual applies to 4000 series shavers, for example model "4740" here. It was also used for a "SmartControl Classic" model.
Step 2

The housing is held together by two screws next to the charging port, which are covered by colored caps.

  • The housing is held together by two screws next to the charging port, which are covered by colored caps.
  • The caps are held in place only by friction. Remove them by lifting, for example with a fine needle.
Step 3

Remove housing screws 

  • Remove the screws with a Torx T-10 screwdriver.
  • The screws are not metric flange screws with a wide head. Thread 2.38 mm, flange 2.9 mm. Each flange has a red O-ring for sealing the "washable" housing. In the picture, one of the O-rings has remained in the housing, one is on the screw.
  • Be careful not to lose the O-rings and to reinsert them during reassembly, otherwise the housing will no longer be washable.
Step 4

Dismantle

  • Grasp the shaving head and the housing and pull the shaving head with the internals out of the housing. Some force is required, but no VIOLENCE. Only friction needs to be overcome, no catches, pawls, or similar.
Step 5

Remove and replace the replacement batteries

  • You can now see the inside with two Ni-Cd replacement batteries. Use a non-conductive tool to pry the replacement batteries out of the contact springs.
  • When inserting the new replacement batteries, note the +/- polarity as indicated on the battery holder.
Step 6

Functional testing and reassembly

  • Test the function of the new replacement batteries on the disassembled shaver. It should start when the power button is pressed.
  • If it does not start, the "new" replacement batteries might not be sufficiently charged. Check the voltage of the removed replacement batteries; it should be between 1.0 and 1.2 V. Charge the replacement batteries if necessary.
  • Afterwards, reassemble the shaver, screw the housing together (do not forget the O-ring seals), and reinsert the cover plugs. Then test whether charging works with the built-in charger.
  • You are finished.