FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

How to Test and Replace the Rear Air Duct and Damper on your LG Refrigerator Model LFX25973

Use this guide to test and replace the rear air...

iFixit Library LG Refrigerator LFX25973 Moderate 1 - 2 hours Guide 166714
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

Use this guide to test and replace the rear air duct and damper on your LG model LFX25973 refrigerator. The rear air duct and damper allow cold air from the freezer evaporator to flow into the fresh food (refrigerator) compartment. The damper controls this flow and has a motor to control it. If the damper malfunctions, the cooling of the refrigerator compartment will be affected: either too cold (damper stuck open) or too warm, (damper stuck shut).

Step 1

Unplug your refrigerator

  • Unplug your refrigerator before you begin your repair.
  • If you are testing or repairing the following items, you may also need to shut off and disconnect the water supply:
  • Condenser Fan Motor
  • Compressor Motor and Thermal Overload Device
  • Water Supply Valve Assembly
Step 2

Open the doors

  • Open both refrigerator doors fully.
Step 3

Remove the shelves

  • Lift up the front edge of the shelf to release it.
  • Unhook the shelf and remove it.
  • Repeat the last two steps for each shelf you wish to remove.
Step 4

Remove the crisper drawers

  • Pull the crisper drawers toward you and tilt them up to remove them.
  • Pull the bottom drawer toward you and tilt it up to remove it.
Step 5

Release the drawer frame

  • Lift the front edge of the drawer frame assembly to release it.
Step 6

Remove the drawer frame

  • Pull the drawer frame assembly toward you and remove it.
Step 7

Remove the bracket screw covers

  • Use a spudger to pry out the two center shelf bracket screw covers.
Step 8

Remove the shelf bracket screws

  • Use a Phillips screwdriver to remove the three screws securing the center shelf bracket and air duct:
  • Two 22.4 mm‑long screws
  • One 12 mm‑long screw
  • Remove the center shelf bracket.
Step 9

Loosen the air duct

  • Use a spudger to loosen one edge of the air duct.
Step 10

Reposition the air duct

  • Grasp the air duct and swing it outward.
  • Don't try to remove the air duct fully as it is still connected to the fridge.
  • Move the air duct so that you can access the connector at the bottom.
Step 11

Disconnect the damper motor connection

  • Squeeze the connector and pull it straight out to disconnect it.
Step 12

Remove the air duct

  • Remove the air duct.
Step 13

Test the damper motor resistance

  • If you have a multimeter, you can test the damper motor for proper resistance.
  • Set the multimeter to the ohm setting.
  • Measure the resistance between:
  • The blue and white wires
  • The yellow and red wires
  • The normal resistance value is 373-456Ω for each pair.
  • If the values are out of this range, you can replace the whole assembly. Alternatively, you can cut the tape that holds the styrofoam duct together, remove the damper assembly, and replace it.