FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

REV Robotics Control/Expansion Hub XT30 Connector (Male/Female) Replacement

Use this guide to replace the XT30 power in /...

iFixit Library REV Robotics Control Hub Moderate 15 - 20 minutes Guide 166985
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

Use this guide to replace the XT30 power in / out connectors on a REV Robotics Control Hub or Expansion Hub, commonly used by FIRST® Tech Challenge (FTC) and FIRST® Global Challenge (FGC) teams.

Step 1

Remove 4 screws at the back of the control hub

  • There are Phillips #00 screws located at the back of the Control Hub. Two are located behind a sticker, which you will have to poke through or peel off.
Step 2

Pry open Control Hub Case

  • After unscrewing the four Phillips #00 screws, you will need to pry open the plastic housing of the case to expose the circuit board.
Step 3

Isolating the Board

  • After prying off the plastic case, you should be able to freely remove the board along with the piece of plastic it rests on. Remove the board from this plastic, exposing the electronics.
Step 4

Flip The Board Over locate XT30 Through Hole Connectors

  • After isolating the board flip the board over and locate the XT30 Through Hole Connectors.
Step 5

Desolder and resolder

  • Simply desolder the XT30 you desire to replace, then using either a wick or desoldering iron clean the area.
  • After this, resolder a new XT30 connector ensuring it is oriented correctly.