FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

Amazon Echo Show 10 3rd Gen Microphone Replacement

This guide will walk you through the...

iFixit Library Amazon Echo Show 10 3rd Gen Moderate 1 - 2 hours Guide 168291
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

This guide will walk you through the replacement process for the microphone component found within your Amazon Echo Show 10 3rd Gen device. The microphone is responsible for taking in voice commands for the device to respond to as well as receiving audio during calls. In the event that the microphone board within the device is malfunctioning or damaged, the device (and its Alexa Assistant) may not be responding to voice commands or may not be able to hear them very well; replacement of this component may be necessary if this is the case. Ensure that the microphone is properly turned on with both the physical microphone button and in the settings before committing to disassembly. Please make sure to check the other solutions listed in the Amazon Echo Show 10 3rd Gen troubleshooting page before replacement. This replacement guide requires the user to pry and remove multiple adhesive components. The extended duration of this guide is due to the significant number of small parts that need to be disassembled, rather than the complexity of the disassembly itself

Step 1

Repair step

  • With the Echo device standing upright, firmly grip the base and use the blue opening tool to gently pry the lid from the mesh speaker base.
  • Remove the lid and set aside.
Step 2

Repair step

  • Use a TR8 Torx Security screwdriver to remove the six 9 mm screws from the perimeter of the plastic bezel on the top edge of the device.
Step 3

Repair step

  • Release the adhesive seal connecting the bezel to the main base by inserting a Jimmy underneath the edge, and gently sliding from one side to another.
  • Lift up the outermost edge of the plastic bezel (furthest from the display) to remove it and set it aside.
  • After removing the screws in the previous step, the only thing holding this component in place is glue. You may need to apply a little force to break the seal created by any remaining glue to remove the bezel component. You could also apply a little heat with the iOpener to loosen the adhesive.
Step 4

Repair step

  • Use a Torx T6 screwdriver to remove the five 10 mm screws from the perimeter of the top surface of the base.
Step 5

Repair step

  • With one hand securely holding the neck of the display and the other holding the device base, gently lift the device out of the mesh shell.
  • Place the shell aside.
Step 6

Repair step

  • Tilt the device so that the underside of the display and its neck are facing you.
  • You may need help holding it in this position. Alternatively, you could place the device on a soft surface so it doesn't get damaged.
  • Use a T6 Torx screwdriver to remove the two 5mm screws from the underside of the display neck.
Step 7

Repair step

  • Lift the plate up to remove it from the neck of the device.
  • Set it aside for reassembly.
Step 8

Repair step

  • Use an opening tool to flip up the small locking flap on the ribbon cable connector located in the center of the exposed underside of the display neck.
  • Gently pull the cable out.
Step 9

Repair step

  • Tilt the device so it is in the upright position.
  • Use a TR10 Torx Security screwdriver to remove the four 11 mm screws from the top of the display neck.
Step 10

Repair step

  • Gently lift the display and its connecting neck off of the base.
Step 11

Repair step

  • Insert a Jimmy along the seam of the screen and the shell and slide it along the length to separate the two sides.
  • For this particular step, a careful amount of force may be needed to separate the two parts. The connection is especially tight at the four corners. Use the iOpener to loosen the small amount of adhesive.
Step 12

Repair step

  • Gently separate the display from the base.
  • There is a small amount of glue holding the two components together in the top corner, which may require the user to apply more force when separating.
  • Don't yank the display off as it is connected by a cable.
Step 13

Repair step

  • Hold the display away from the board at an angle to ensure a clear view while keeping the ribbon cable slack.
  • Place the tip of your opening tool under the edge of the display connector, and pry the connector straight up from its socket.
  • Be very careful to pry only under the edge of the connector, and not under the socket itself. If you pry under the socket, you will separate it from the circuit board, which requires specialized microsoldering skills and equipment to repair.
  • Set aside the display.
Step 14

Repair step

  • Place the tip of your opening tool under the edge of the orange connector, and pry it straight up from its socket.
  • To reconnect, align the connector carefully over its socket and press down with your fingertip—first at one side, then the other—until it clicks into place.
Step 15

Repair step

  • Use the T5 Torx screwdriver to remove the two 4 mm screws from the bracket covering the microphone board and the one 4 mm screw holding down the board itself.
Step 16

Repair step

  • Use a spudger to pry under the microphone board. and gently wear away at the connecting glue.
  • The board is glued on so use the spudger to release the glue. It may take some time but be patient to avoid damaging the device.
  • The microphone component is delicate and relatively flimsy, so a gentle approach to breaking the adhesive is recommended.
  • After the adhesive seal has been broken, gently lift and remove the microphone board.