Equation DL06 Stand Air Convector, dead, does not turn on.

Attributed iFixit repair guide for Convector Aire EQUATION DL06 Stand 1800 - 2000 W.

iFixit Library Convector Aire EQUATION DL06 Stand 1800 - 2000 W Easy 45 minutes Guide 170816
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Step 1

Repair step

  • Completely dead air convector. We attended to and resolved this fault at Repair Café Palma with the resources we had, which were "limited." A solution was provided so that the owner could take the device home; it is solved.
  • The device was completely dead; neither of the two buttons with the neon indicator light would turn on.
  • It is an air convector or heater, very basic and simple, which only contains a double resistance, a working thermostat (button), a safety thermostat, and a thermal fuse AS A DOUBLE SAFETY SYSTEM. In these, the thermal fuse usually fails due to excessive overheating. Therefore, we went straight to testing the thermal fuse.
  • The entire teardown is not detailed as it is very basic and the location of all the screws and the release of the cover are visible.
Step 2

Repair step

  • Red arrow: Working thermostat, "adjustable".
  • Orange arrow: Safety thermostat, in case the working one fails.
  • Green arrow: Thermal fuse, this is the equipment's problem; this fuse performs the function of a "double safety system" in the event of excessive overheating; they tend to blow or burn out quite easily.
  • After checking the thermal fuse with a multimeter on the ohms or continuity setting, it shows an open circuit, it is burnt out.
  • Proceed to cut it "flush" to reuse without 2 terminals with the substitute, after evaluating several possible solutions since we did not have a drill and drill bit to break the 2 rivets and place 2 screws with nuts in their place.
Step 3

Repair step

  • Defective thermal fuse rated at 157°C 10 A
  • It is important to be able to see the markings to search for information on Google. AUPO BF157
  • https://www.google.com/search?q=AUPO+BF+...
  • It seems impossible that, years ago, we were able to perform repairs without all the facilities for obtaining information that we have today.
Step 4

Repair step

  • Replacement: We can never install a thermal fuse with a lower temperature and amperage rating; it must always be of an equal or higher temperature. In this case, we have a 192° thermal fuse from a coffee maker, which is the one we will use. We will secure it using two electrical terminal blocks from which we have removed the plastic casing.
Step 5

Repair step

  • The 2 terminals of the fuse will bend outward so that the new thermal fuse can be hooked onto them, since we do not have a drill today to remove the rivets and enlarge the hole to install screws.
Step 6

Repair step

  • I measure the new thermal fuse, bending and adapting its terminals to the 2 terminal blocks.
  • Related repair guide, dedicated to thermal fuses. https://es.ifixit.com/Gu%C3%ADa/Recopila...
Step 7

Repair step

  • Once the thermal fuse has been replaced, check that it will not rub against the metal plate of the casing; before closing the device, test it.
  • It now turns on correctly and heats up; NOTE: any accumulated dust will smoke as it burns off with the heat, this is completely normal.
  • View of our workbench with volunteers and upgrade kits at Repair Café Palma.
  • Device reassembled, functioning.
  • END of the Guide.