FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

Graef WK 901 - switches off immediately

Within the frame of a Repair Cafe, I got my...

iFixit Library Graef WK 901 Moderate 30 minutes Guide 170976
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

Within the frame of a Repair Cafe, I got my hands on a Graef WK901. It switches off immediately after starting. Since the kettle is electronically controlled, a transformer is integrated on the PCB for this purpose. The heating coil of the kettle is controlled via a relay. As soon as the relay is activated by the electronics, the device switches off. Apparently, the power supply for the electronics collapses. For this reason, we took a chance and replaced the two capacitors with equivalent capacitors. The kettle works again. Unfortunately, we did not take any pictures. But that should not be a problem. Simply unscrew the kettle (container) from below and release the PCB. The PCB can stay attached to the heating element and does not need to be desoldered. The same electronics should be installed in the Graef WK 701. The link to the simple model of the Graef WK 402 without electronic control: https://de.ifixit.com/Anleitung/Graef+WK...

Step 1

Unscrew the bottom panel

  • The bottom panel is secured with a triangular screw.
  • Photos of the internal components are unfortunately missing. If anyone has these photos, please send them to me. I will then add them here in the guide.
Step 2

Internals

  • Here are a few more pictures of the internals that were sent to me by a kind reader.
Step 3

Replace the capacitor

  • Now replace the two capacitors. For the values, see replacement parts in the guide details.
  • The PCB is secured with a screw and can be folded up on one side after it is released.
  • Additionally, a 5.5V 0.3F supercapacitor is installed. If this becomes weak, the display will go blank immediately after lifting the boiler from the base unit. With an intact capacitor, the temperature should remain displayed for 5 minutes according to the guide.