Step 1

Prepare Work Area

  • If available, find a clean work surface to set up tools and supplies to prevent contamination.
  • Pictured is a cart with cardboard. This is the recommended setup.
  • Confirm all provided parts have been received. Any missing parts should be reported to RESM and Customer Support Team with a picture of all parts that have been received.
  • Establish a zone of safety around the work area.
  • NOTE: Nitrile rubber gloves are the more appropriate gloves for this replacement.
Step 2

Using manual mode, raise the jaw to release pressure against the EPS block.

  • Jaw should not be up all the way to prevent tension when replacing the cylinder in future steps
Step 3

Perform Lockout Tagout

  • Power off densifier at the control panel while jaw is in the up position.
  • Apply LOTO device to the service disconnect.
Step 4

Prepare the Densifier for Cylinder Removal

  • Remove the guard using 13mm socket wrench
  • Place absorbent materials (e.g. Pigmats, towels) to catch fluids.
  • Use available material to stabilize plate above the existing block.
Step 5

Remove the Cylinder.

  • TIP: Using zip ties to secure the hoses to the asset in an upright position will prevent drips or leaking.
  • Disconnect the top hose from the flow control valve.
  • Disconnect the bottom hose from the cylinder.
  • Unscrew bottom cylinder fitting, capturing any oil that may discharge in a small cup or disposable container. Plug hole with a paper towel.
  • Remove of cotter pins from each of the two (2) cylinder retaining pins, then dislodge retaining pins.
  • Cylinder may be removed carefully as to prevent oil from spilling.
Step 6

Prepare the New Cylinder

  • Remove the fittings from the old cylinder. Save for later.
  • Lubricate the new cylinder by adding NLGI #2 grease to both grease fittings.
  • Assemble the filter and fittings onto the new cylinder.
Step 7

Install New Cylinder

  • Insert new cylinder with supplied filter and reused flow control valve.
  • Return the retaining pins and secure with cotter pins.
  • Reattach bottom cylinder fitting.
  • Reconnect the bottom hose to the cylinder.
  • Reconnect the top hose to the flow control valve.
Step 8

Prepare the Densifier for Operation

  • Remove the stabilizing prop between plate and existing block.
  • Remove LOTO device from service disconnect. Re-energize the asset.
  • Power on the densifier at the control panel.
Step 9

Confirm Successful Installation of Cylinder

  • Exercise the jaw using manual mode for six (6) full strokes, noting that Down then up is counted as one (1) stroke. Leave in down position when completed.
  • Return to Auto Start mode when completed.
  • Check for leaks at the cylinder and hoses.
  • Check hydraulic oil levels, replenishing with #46 oil as necessary.
Step 10

Perform Operations Check

  • Feed densifier with Styrofoam to ensure equipment operates as normal.
Step 11

Check for Magnets

  • There should be a total of four (4) Magnets (Part Number DPFV-MAGNET). The magnets should either be in use or located in the electrical cabinet.
  • Take picture(s) of all four (4) magnets.
  • Any missing magnets not captured in pictures should be advised in the service notes.
Step 12

Clean Work Area

  • Reinstall guard onto densifier, ensuring no pinch points.
  • Wipe equipment surfaces and sweep excessive Styrofoam on floor.
  • Discard oil in Hazmat area.
  • Collect tools, supplies, and items used for Zone of Safety.
Step 13

Return Old Cylinder to Customer

  • Use included Return Label found behind the original label.
  • Drop of package at the nearest FedEx location.