Prusa i3 MK3 Y-Axis Bearings Replacement

If the Y-axis bearings in your PRUSA i3 MK3 are...

iFixit Library Prusa i3 MK3 Moderate 30 minutes Guide 171600
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

If the Y-axis bearings in your PRUSA i3 MK3 are worn and need to be replaced they might make noise and prevent the heat bed from moving smoothly. If you need to replace the Y-axis bearings in your PRUSA i3 MK3, follow the steps in this guide. Ensure that you do not lose any of the parts or screws that are removed during replacement.

Step 1

Repair step

  • Orient the printer so that the screen is facing to the left.
  • Using the On/Off button, switch the printer into the Off position.
  • Ensure your printer is off by visually inspecting the screen. If the screen is not lit up, your printer is off.
  • Ensure the printer has cooled to room temperature before beginning disassembly.
Step 2

Repair step

  • Orient the printer so that the screen is facing you.
  • Move the X-axis carriage to the highest Z-axis height for optimal accessibility.
  • Remove magnetic build plate.
Step 3

Repair step

  • Remove the nine 2.5mm X 12mm flat-head countersink screws from the heat bead.
  • Lift and set the heat bed aside to access the heat bed mounting bracket.
Step 4

Repair step

  • Orient the printer so that the screen is facing away from you.
  • Remove the two 2.5mm X 10mm socket head screws holding the Y-axis belt motor bracket.
  • During reassembly, these screws will be used to properly tension the Y-axis belt.
Step 5

Repair step

  • Use the side cutters to cut and remove the four zip ties that secure the Y-axis rods.
Step 6

Repair step

  • Lift the heat bed mounting bracket assembly from the printer.
  • Remove the Y-axis rods from the heat bed mounting bracket assembly.
Step 7

Repair step

  • Rotate the heat bed mounting bracket assembly to access the bottom side.
  • Remove the Y-axis belt from the Y-axis belt grip.
  • Remove the heat bed mounting bracket assembly and set it aside to complete the next steps.
Step 8

Repair step

  • Orient the heat bed mounting bracket so that you are looking at the top side.
  • Use the 5.5mm nut driver to remove the six 5.5mm u-bolt nuts.
  • Orient the heat bed mounting bracket so that you are looking at the bottom side.
  • Remove the three sets of U-bolts and Y-axis bearings.
Step 9

Repair step

  • During reassembly, grease the Y-axis bearings with the PRUSA Lubricant Applicator.