Cleaning the DeLonghi EN 550.S Latissima Touch brewing unit

If water or coffee ends up in the capsule...

iFixit Library Nespresso Delonghi Lattissima Touch Moderate No estimate Guide 172927
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

If water or coffee ends up in the capsule drawer instead of in the cup, you need to check the brewing unit. A thorough cleaning will probably suffice.

Step 1

Preparations

  • Never forget: Unplug the machine before starting repairs.
  • Remove all attachments such as the water tank, milk tank, and capsule drawers.
Step 2

Remove the back cover

  • Turn the device over so that the back is facing you.
  • Remove the four Phillips screws.
  • Remove the back cover; it may be a little stuck.
Step 3

Remove the right side panel

  • Pull the right side panel back by about 1cm and remove it
Step 4

Unscrew the top cover

  • The top cover is secured with a Phillips screw under the side panel. Unscrew that screw.
  • Push the cap behind the lever for the brewing unit back about 1 cm and remove it.
Step 5

Remove the top cover

  • The top cover is still connected to the motherboard by a ribbon cable.
  • The connection is fragile! If the connector is too tight in the socket, it can tear off the board. This will damage the board!
  • Bend the two tabs on the sides of the connector to the side using a small flat screwdriver.
  • Use a suitable tool, e.g., small needle-nose pliers. Be extremely careful when pulling the connector toward you. Work slowly and patiently.
Step 6

Repair step

  • Press the top cover firmly toward the front and lift it over the lever of the brewing unit
  • When reassembling, make sure that the pin on the power button fits into the opening on the gray plastic part.
Step 7

Repair step

  • Pull out the metal clamp on the pressure hose to the brewing unit using needle nose pliers
  • Pull out the pressure hose
Step 8

Repair step

  • There are two Phillips screws on each side of the brewing unit. Remove those.
  • Lift the brewing unit out.
Step 9

Repair step

  • Release the two tabs on the sides of the coffee spout.
  • Remove the coffee spout. It is likely to be stuck, so you may need to use a suitable tool to gently pry it loose
Step 10

Repair step

  • Clean the inner and outer coffee spout.
  • To ensure that the coffee grease deposits are easily removed, it is best to place the front part of the brewing unit in a hot solution with dishwasher detergent. After a while, you can remove the dirt with a toothbrush.
Step 11

Repair step

  • Now you need to clean the pyramid plate that pierces the capsules.
  • Insert a small flat screwdriver into the opening on the brewing unit. Carefully push out the pyramid plate.
  • Note its position, as it will have to be reinserted identical later on.
Step 12

Repair step

  • Here you can see the pyramid plate before and after cleaning. Check that all holes are cleared.
  • If the plate it to badly worn, replace it.