FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

Nespresso KRUPS XN 100110 coffee machine electronic board failure: Burnt varistor + melted copper trace.

Attributed iFixit repair guide for Cafetera Nespresso KRUPS XN 100110.

iFixit Library Cafetera Nespresso KRUPS XN 100110 Moderate 1 hour Guide 172982
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Step 1

Repair step

  • To reach this point of the Teardown, it is explained in Guide 1.
  • This guide is dedicated to looking at the problem of a dead coffee maker, completely OFF due to a failure of the electronic board, with a burnt varistor that has melted the power input copper trace.
  • Views of the electronic board.
Step 2

Repair step

  • One detail I really don't like about this machine and others similar to it that use the same circuit board is that it mixes ELECTRONICS, ELECTRICITY, AND A WATER CIRCUIT, since the flowmeter that water passes through from the tank to the water pump is attached to the circuit board.
  • Since the flowmeter spins and the transistor counts the rotations by means of a HALL effect magnetic transistor, the slightest water leak would directly attack the circuit board; WATER + ELECTRICITY is not a good combination.
  • Photo 1: Flowmeter.
  • Photo 2: Blown, burnt varistor; this was the cause of the failure.
Step 3

Repair step

  • Views of the PCB from the side with the copper traces and solder joints.
  • Note: A varistor is a resistance that activates in the event of an overvoltage; in this case it is 275, = 275 V which begins to conduct electricity when the network exceeds that voltage. It is in parallel with the F-N power input, so when it conducts electricity it causes a short circuit, which is why when we have a varistor on a PCB.
  • We will always have associated with it a fuse, or a copper fuse trace, or a trace that will act as a fuse, which is what happens in this case (I have seen the same breakdown in 2 different machines and it is not a coincidence...)
  • Apart from replacing the varistor, the really important thing in this repair is to replace the blown trace.
  • Photo 2: In these repairs, a flashlight is very helpful for identifying the path the "volatilized" copper used to take.
Step 4

Repair step

  • Using a permanent marker, I mark the position of the varistor and the path the copper trace should follow on the board.
Step 5

Repair step

  • Disconnected from the airflow sensor on the board to be able to work with more comfort and space, we see the Hall-effect field-effect transistor, (IC2)
Step 6

Repair step

  • The volatilized copper trace connects the power input (Photo 1) to the varistor pin (Photo 2).
Step 7

Repair step

  • Varistor measurement, it is not strictly in short circuit, but it measures 537 ohms when it should measure Megaohms and it is cracked and burst, so it is completely burnt.
Step 8

Repair step

  • Varistor value views, K275 = 275 V as it is for a machine powered at 230 V.
  • Fault Video.
Step 9

Repair step

  • In this document, I am not showing the replacement of the varistor and the repair of the copper trace, as I am going to dedicate another document to another coffee maker of a different model with the exact same failure (the other one is in much worse condition).
  • Repair: replace 275V varistor and redo the trace between the input faston terminal and the varistor pin.
  • As soon as I have the other guide prepared, I will attach it here.
  • END of the Guide 2.