FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

Guide 3: DIY Tool, Simple dead battery test for Robot Vacuum using an automotive turn signal bulb.

Attributed iFixit repair guide for Robotic Vacuum Cleaner.

iFixit Library Robotic Vacuum Cleaner Very easy 5 minutes Guide 173110
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Step 1

Repair step

  • Simple, basic 14.4 V dead battery tester for most domestic cleaning robot models.
  • I built another tester that measured the battery voltage at the same time, but since I understand that creating the test PCB LINK TO THE TEST PCB DOCUMENT is not within everyone's reach, I have decided to make something much simpler and easier for any upgrade kit to make.
  • Another link improving the previous design:
  • On this occasion, the simple proposed tester consists only of a car turn signal bulb (classic bulbs that are very easy to find), 2 wires, and 2 alligator clips.
  • Examples 12 V 21W bulb.
Step 2

Repair step

  • Required Materials:
  • 1 21 W 12 V automotive turn signal bulb.
  • 2 pieces of red and black wire.
  • 2 red and black alligator clips (optional).
  • 1 piece of 15 mm wide heat shrink tubing in any color.
Step 3

Repair step

  • The soldering process is very basic: heat with the soldering iron, tin the wire, and solder.
Step 4

Repair step

  • Solder details.
Step 5

Repair step

  • If the heat shrink tubing is not the right size, you can stretch it "a little" using pliers or scissors.
Step 6

Repair step

  • Place the heat shrink tubing and heat it with a lighter or a hot air gun so that it shrinks.
Step 7

Repair step

  • Example of a robot vacuum cleaner 14.4V dead battery model to test.
Step 8

Repair step

  • Battery test: The light emitted by the lamp must be bright. Apply a 0.4A load to the battery; if we use a multimeter on the DC voltage scale, we can see the battery voltage at rest and with a load connected. If the battery is okay, the voltage should not drop by more than 1 V.
  • If the bulb barely lights up, the battery might have measured a voltage of 14.4V correctly, but it does NOT actually hold a charge. DEAD BATTERY, WORN-OUT BATTERY.
  • Another example document on using the lamp.
  • And another example with a design modification.
Step 9

Repair step

  • Finally, for use as a protective, shatter-proof container for the lamp, as well as for transport and storage, you can use a tube or pill bottle. In this case, I have used one for effervescent tablets; if the cables are not left excessively long, it fits perfectly.
  • Note: insert the bulb first; if you do it the other way around, you won't be able to get it out. Haha. As you can see in photo 3, you can pull the cables perfectly to take it out.
  • END of Guide.