Step 1

Repair step

  • Teardown of the Krups XN 304 coffee maker model and others similar, such as the XN 100*.
Step 2

Repair step

  • Remove the 4 Torx screws from the 2 side covers.
  • The covers, apart from being held in place with 4 screws, are snapped into the bottom, left, and right sides.
  • Once the 4 screws are loose, use a small lever on the sides.
Step 3

Repair step

  • Remove the right-side cover. We recommend marking which side each cover belongs to with a marker.
Step 4

Repair step

  • Before proceeding to disassemble anything further, if the machine would not turn on, we will check that there is input voltage at the 2 white faston connectors, just to rule out a problem with the power input cable; as we can see, this is okay.
  • Plug the machine into the power outlet.
  • Check for voltage at the 2 white Power Cable Connectors.
  • Once voltage is confirmed (in my case, 230 V AC for Spain), unplug the machine from the power outlet.
Step 5

Repair step

  • Remove the left side cover in the same way by removing the 4 screws and prying gently on the sides.
Step 6

Repair step

  • In the Closed position, remove the capsule holder handle by removing the two T15 Torx screws.
Step 7

Repair step

  • Covers and handle removed.
Step 8

Repair step

  • With the machine unplugged from the power supply, disconnect the power cable.
  • To remove the inverted U-shaped cover from the reservoir inlet, you must pry first on the right side, PLEASE NOTE THIS IS VERY IMPORTANT; if you pry on the left side, you will break the inside of the cover.
Step 9

Repair step

  • With the cover removed, you can see the indentations on the base and the 2 tabs on the cover that break if you remove it from the left side.
Step 10

Repair step

  • 1st Remove the white cable clip. This part is the only simple part of this step.
  • 2nd This step is somewhat complex; to extract the machine casing, use a pry tool in the center to unhook it.
  • 2nd Unhook the top cover. CAUTION: CHECK THAT THE CAPSULE PRESS IS IN THE CLOSED POSITION. Otherwise, the cover cannot be removed.
  • Be patient during this part, as it does not always come off on the first try; you have to persist and use a flathead screwdriver to pry it off bit by bit.
Step 11

Repair step

  • On this model, there is a small cover on the bottom of the cable that must be removed.
Step 12

Repair step

  • Once the housing is unhooked, it opens like a book and can be removed.
  • The cable is removed by disconnecting the 2 faston connectors with white connector and the ground faston.
Step 13

Repair step

  • The bottom cover is not removed, as it is essentially the base of the machine. The next part to remove would be the capsule press block + boiler + water pump assembly that is fitted into the bottom cover.
  • I am not disassembling it, since in this case we were interested in reaching the electronic board. We can carefully separate the casings to disconnect the 2 bottom connectors and remove it.
  • END of Guide 1:
  • Other guides in this series: Cafetera Nespresso KRUPS XN 304