Synology DS1522+ Cooling Fan Replacement

This guide shows how you can replace the...

iFixit Library Synology External Storage Moderate 1 - 3 hours Guide 174275
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

This guide shows how you can replace the cooling fans in the Synology DiskStation 1522+. The cooling fan installed by Synology is a Y.S TECH FD129225LL-N DC 12V 0.12A 90x90x25mm 3-Wire Server Cooling Fan. In the NAS data sheet, the dimensions are specified as 2x (92 x 92 x 25 mm). As a replacement, Noctua NF-A9 FLX 92mm Premium cooling fans are installed in this guide.Note that these press the cover slightly outward in some places, but are otherwise suitable for the device. You can also use this guide to clean dust and dirt from the cooling fan.

Step 1

Preparing the NAS for opening

  • Before you begin the repair:
  • Shut down the NAS.
  • Disconnect all cables and connected devices.
Step 2

Unscrew the cover

  • Remove the eight 9 mm Phillips PH2 screws shown that secure the cooling fan.
Step 3

Pry off the cover

  • Pry off the cover at the top and bottom corners.
  • The cover is held in place at the marked spots on the device.
Step 4

Removing the network card expansion slot cover

  • Remove the two 5 mm Phillips PH 2 screws shown.
  • Remove the cover or the 10GbE expansion card.
Step 5

Remove the housing

  • Remove the two 1.4 mm Phillips PH 1 screws.
  • It is best to remove your hard drives before the next step.
  • Then slide the upper housing forward and then outward.
Step 6

Removing the expansion slot tray

  • Remove the expansion slot tray to have more clearance.
  • To do this, remove the two 5 mm Phillips PH2 screws on the back of the device.
  • Also remove the two 7 mm Phillips PH2 screws on the bottom.
  • Now remove the tray by first pulling the right side toward you. This makes it easier to remove the part.
Step 7

Disconnect the cooling fan cable

  • Slightly bend the plastic clip pointing toward you, and with your other hand, pull the cooling fan cable socket upward.
  • Repeat this for the other cooling fan.
Step 8

Remove the cooling fan

  • Unscrew the two retaining arms.
  • To do this, remove the two Phillips PH 2 screws.
  • Lift the cooling fans, along with the retaining arms, out of the housing.
  • Now pull the retaining arms off of the cooling fans.
Step 9

Preparing the new cooling fans

  • When installing the new cooling fans, ensure they move air in the same direction as the old ones. In this case, the cooling fan pulls air from inside the device and exhausts it out the back.
  • There are two arrows on the cooling fans. One points forward/backward to indicate the airflow direction, and the other points to the side to indicate the direction of rotation.
  • Prepare the cooling fans before installation and consider how to orient them so that the cables are not lying everywhere inside the device, as the new cooling fans have significantly longer cables than the removed ones.
  • Now attach the bracket back onto the cooling fans at the appropriate spot (rear right corner). The bracket may be slightly overstretched if the frame is thicker than that of the old cooling fans. You may also need to remove the rubber anti-vibration corner attached to some cooling fans at that location.
Step 10

Installing the cooling fan

  • Place your device on its side.
  • Slide the cooling fans into the device from the left, making sure to route the cables downward for now.
  • Secure the two retaining arms again with the previously removed Phillips PH 2 screws.
  • The cooling fan that was further from the cooling fan connector during removal was attached to the left connector.
  • Plug the cooling fan connectors back in.
  • Now you can transfer the tape from the old cooling fans to the new ones, so the cables lie a bit more neatly in the device.
Step 11

Securing the cooling fan

  • Snap the cover back onto the device from the outside.
  • Now secure the cooling fans with the eight 9 mm Phillips PH2 screws from the beginning.
  • Depending on the cooling fan, it is possible that the cover will be pushed out slightly in some places.
Step 12

Install the expansion slot cover

  • Insert the left side first, then the right side, into the housing.
  • Secure the cover with the two 7 mm Phillips #2 screws on the bottom of the device.
  • Now secure the cover with the two 5 mm Phillips #2 screws on the back of the device.
Step 13

Securing the housing

  • Slide the housing onto the device from the side, positioning it slightly further forward than the rest of the unit.
  • Once the housing touches the other part already attached to the device, slide it backward along the device so that the two parts fit together again.
  • Now, fasten the two 1.4 mm Phillips PH 1 screws on the back to hold both parts together.
Step 14

Securing the network card expansion slot cover

  • Insert the expansion with the bottom edge first.
  • Secure it with the two 5 mm Phillips PH 2 screws.