Opening Philips EP-Models

For most repairs, you have to open the device....

iFixit Library Philips EP2200 Moderate No estimate Guide 174879
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

For most repairs, you have to open the device. This isn’t a big problem with the EP models. Note: EP 5xxx models are from an older Saeco line. Compare with Saeco Minuto. This guide can also help with Saeco-models and with other fully automatic coffee machines from Philips and Gaggia - the devices all come from the same manufacturer and are very similarly built.

Step 1

Repair step

  • Don't forget to unplug the power cord!
  • Remove all attachments, like the water reservoir, the brewing chamber, the bean compartment lid, and the drip tray. Remove all of the coffee beans.
  • Turn the machine around so the back is facing you. Remove the two T10 Torx screws at the bottom edge. Pull out the back at the bottom edge and lift it down.
  • It's important that these parts are readily visible:
  • The motherboard
  • The pump
  • The flow meter
  • The heating element
Step 2

Repair step

  • Unscrew the three T10 Torx screws in the coffee bean compartment.
Step 3

Repair step

  • Remove all the beans from the opening on the finger guard of the grinder. A T10 Torx screw will be visible in the center of the finger guard.
  • Unscrew the T10 Torx screw from the finger guard.
  • Lift the finger guard up.
Step 4

Repair step

  • Slightly lift the top cover up at the back edge.
  • When putting it back together, make sure the grinder control is sitting right.
Step 5

Repair step

  • Pull the upper cover out from under the front cover and lay it slightly offset.
  • Remove both of the T10 Torx screws attached to the side covers.
  • You can remove the top cover completely, especially if you must work on the grinder. But, if you want to see the machine functioning later, then lay it back in its original place.
  • Picture 2 shows the grinder, which can now be easily taken off.
  • If you want to repair the grinder: here are the instructions Replacing the Philips ceramic grinder motor and sensor
Step 6

Repair step

  • Both side panels are still screwed to the lower edge of the front. Unscrew both of the T10 Torx screws out from here.
  • Slide both side panels back a bit, and take them out from the bottom edge.