Philips EP models: pump replacement

These instructions show how to replace the pump...

iFixit Library Philips EP2200 Moderate No estimate Guide 174880
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

These instructions show how to replace the pump in Philips EP models. The instructions can also help with Saeco models and with other Philips and Gaggia coffee machines – the devices all come from the same manufacturer and are very similar in design.

Step 1

Repair step

  • Don't forget to unplug the power cord!
  • Remove all attachments, like the water reservoir, the brewing chamber, the bean compartment lid, and the drip tray. Remove all of the coffee beans.
  • Turn the machine around so the back is facing you. Remove the two T10 Torx screws at the bottom edge. Pull out the back at the bottom edge and lift it down.
  • It's important that these parts are readily visible:
  • The motherboard
  • The pump
  • The flow meter
  • The heating element
Step 2

Repair step

  • Unscrew the three T10 Torx screws in the coffee bean compartment.
Step 3

Repair step

  • Remove all the beans from the opening on the finger guard of the grinder. A T10 Torx screw will be visible in the center of the finger guard.
  • Unscrew the T10 Torx screw from the finger guard.
  • Lift the finger guard up.
Step 4

Repair step

  • Slightly lift the top cover up at the back edge.
  • When putting it back together, make sure the grinder control is sitting right.
Step 5

Repair step

  • Pull the upper cover out from under the front cover and lay it slightly offset.
  • Remove both of the T10 Torx screws attached to the side covers.
  • You can remove the top cover completely, especially if you must work on the grinder. But, if you want to see the machine functioning later, then lay it back in its original place.
  • Picture 2 shows the grinder, which can now be easily taken off.
  • If you want to repair the grinder: here are the instructions Replacing the Philips ceramic grinder motor and sensor
Step 6

Repair step

  • Both side panels are still screwed to the lower edge of the front. Unscrew both of the T10 Torx screws out from here.
  • Slide both side panels back a bit, and take them out from the bottom edge.
Step 7

Repair step

  • The pump is clearly visible in the back. It is installed in a vertical position and held by a rubber bracket.
  • To be on the safe side, remove the three black cables of the flowmeter from their holder so that the pump has a free path.
  • Pull the two flat connectors off the pump.
  • The thermal fuse on the cable is glued to the pump at the factory. Carefully scrape off the adhesive and pull the thermal fuse out downwards.
  • When reassembling, attach the thermal fuse to the new pump with a piece of electrical tape.
Step 8

Repair step

  • The rubber holder for the pump is hooked at the top. Push the rubber hook away from you with a metal spatula and leave the metal spatula in place.
  • Take a strong screwdriver and now push the bracket with a lot of force towards the water tank side until it gradually comes out together with the pump.
  • Lift out the pump. It is still connected with two hoses.
Step 9

Repair step

  • Pull the pump out of the lower water connection.
  • Insert a 12 mm open-end wrench into the upper pump outlet.
  • Turn the black connection slightly counterclockwise until it comes loose.
  • Turn the pump all the way out.
  • Take care of the seal on the upper connection. Replace it if necessary when replacing the pump.
Step 10

Repair step

  • The factory-installed pump was an Ulka EP5FMGW. Replace it with an Ulka EX5, which has a metal fitting.
  • Ulka pumps can be opened and possibly repaired, but replacement is usually better.
  • Secure the thermal fuse to the pump with electrical tape.