Before you begin
The FF-98 Controller is a mains-powered electronic water level sensor and alarm containing a 120VAC 20A relay for powering a sump pump. It detects water via two single conductor wire probes, one to activate the pump and one mounted higher up to activate a built in alarm if the pump fails. It has an adjustable timer from 0 to 80 seconds that controls how long the pump remains powered after the water level is reduced below the ‘pump’ sense wire. It was desired to have a battery powered backup for the sump pump system. The previous solution was a 12V automotive battery, a charger, and pump, but it would have to be manually disconnected from the charger and switched on if the power ever went out. The secondary alarm sensing function was repurposed to control a second 12V relay which would operate the pump automatically. The battery also powers the detection circuitry of the AC power fails. Goals: Maintain current 120V operation and safety.Allow seamless change-over to battery-powered operation.Give priority to the 120V pump.Provide a 12V PUMP ON indicator.Provide a 12V pump test function.Disconnect the charger to prevent possible damage while operating the pump.Minimal modification to existing circuit board and housing. If you would like to modify your own unit, a measured drawing is available and you'll read more about that before this post ends. I have also included a full schematic and reverse engineering of the circuit for reference or incorporation into other projects.