Before you begin
The Mercury Recovery procedure ensures the safe extraction of mercury switches from appliances while working in the Market Delivery Operation (MDO) facilities. Mercury found in ranges or gas ovens will be housed within a probe and thin steel capillary connected to the gas control valve. To ensure safe mercury recovery, the technician must remove the entire assembly — including the valve body, capillary, and probe — in one piece, taking care not to damage the capillary. Regardless if mercury switches were found or not, the technician should place a completion sticker over the “May Contain Mercury Switches NEEDS INSPECTION” sticker to signify that the unit was inspected. IMPORTANT: If Mercury is released during recovery, the technician should contact the MDOM and 3E for cleanup and rope off the area with safety cones and caution tape. To recover mercury switches from ranges or gas ovens, complete the following steps: