Step 1

Repair step

  • Electronic bathroom scales are complex devices with very few components, making them difficult to repair. We can only check a couple of things; if the problem isn't one of those, there is nothing we can do for them.
  • The one covered in this document had a sulfate problem in one of the batteries. They were replaced (note: always replace all 2 or 4 batteries the device uses so that they all have the same charge). However, after replacing the batteries, it wouldn't turn on; the metal plate of the battery holder was cleaned without success.
Step 2

Repair step

  • The scale has no screws and is held together entirely by pressure-fitted clips, so use a thin-bladed knife to pry along the sides.
  • TIP: To avoid scratching the white paint on the base, as it scratches very easily, cover the non-cutting side of the knife blade with a piece of electrical tape (I did not do this in this case). This will prevent the risk of scratching the base; in any case, proceed slowly and with extreme caution.
Step 3

Repair step

  • Cover unseated... this allows us to work with it at a 90º angle, and we can immediately observe the problem: the black wire has snapped due to battery corrosion (corrosion eats away at and cuts through the copper, especially when the wire is thin).
Step 4

Repair step

  • To perform a deep cleaning of the terminal, bend the 2 inner plates and extract the metal sheet, so it can be properly cleaned outside and sandpaper can be applied to the contact.
Step 5

Repair step

  • Reposition the contact.
  • Bend the 2 inner metal plates.
  • Apply electronics soldering iron and a little solder to provide a surface for soldering the wire; I recommend cleaning the soldering point beforehand with a piece of sandpaper. If we did this in step 4, even better.
Step 6

Repair step

  • The tip of the cable is heavily damaged and sulfated, so trim about 3 or 4 mm by stripping the insulation to obtain a "clean, shiny" cable tip that can be soldered.
  • Apply a solder joint to attach the cable to the battery holder plate.
  • Replace the batteries and test the scale; if it doesn't recover, it is not worth spending any more time on it, as there is nothing else we can do.
  • END of Guide.
Step 7

Repair step

  • repair scale