Step 1

Repair step

  • Since this robot vacuum model is a few years old, it was built with an "accessible battery" philosophy; current models are no longer like this and require disassembling the entire base.
  • Using the 2 screws, remove and take off the battery cover.
Step 2

Repair step

  • With the cover removed, we can see that the dead battery has a pull tab to lift it. CAUTION: the connector for the dead battery in this robot is somewhat difficult to disconnect, but even harder to reconnect. A negative point to the manufacturer for not using 3 cm more cable.
Step 3

Repair step

  • Characteristics of the 14.8 V dead battery, a very typical voltage for this type of device.
Step 4

Repair step

  • As seen in photo 1, the connector is located inside the chassis, which makes disconnecting it possible, though quite difficult. I used a thin screwdriver to pry open the locking tab and a pair of small tweezers to hold it, with significant difficulty.
Step 5

Repair step

  • We are going to look at two types of tests that we can perform on the dead battery:
  • 1st Voltage measurement with a multimeter on the DC Volts scale, at the 25V setting or similar; in this case, it measures 14.61 V, which is initially a good sign, but we are going to verify if it can actually supply output current. For that, there are two methods: one very simple one using a light bulb and another using a homemade tool that I already showed you in another guide.
Step 6

Repair step

  • 1st method for testing the dead battery with a homemade tester, which has a built-in voltmeter and applies one or two resistances that place a significant load on the dead battery; we will see if the voltage drops slightly or significantly under that load.
  • Guide where I explain the construction of the tester:
  • Guide 4 A: Battery tester for CONGA - COMBA and ROOMBA cleaning robots (14.4 V) applying a 1 Amp load.
  • Guide 4 B: Improvement: Reverse voltage protection for the CONGA - ROOMBA cleaning robot dead battery tester.
Step 7

Repair step

  • Photo 1: dead battery voltage without load.
  • Photo 2: dead battery voltage with a 0.375 + 0.650 = 1.025 Amp load applied; it handles it perfectly, with the dead battery voltage remaining at 13.3 V.
  • Dead battery tested and is in good condition; if the voltage drops below 11 V, it should be replaced.
Step 8

Repair step

  • 2nd Alternative check, assuming you haven't built the homemade tester.
  • We can use a 12V - 21W automotive turn signal or brake light bulb with a single filament. Solder 2 pieces of wire to it and plug it into the dead battery connector. The bulb should light up at practically 100% brightness if we can measure the voltage with a multimeter at the same time.
  • We will see a voltage similar to the one we observed with the homemade tester.
  • Guide where I explain how to build a bulb setup to make it a bit more professional.
  • Homemade tool, simple check with a light bulb for the Robot Vacuum dead battery.
Step 9

Repair step

  • To reconnect the dead battery once checked, we must use tweezers, the longer the better, and a thin screwdriver. I won't lie to you, it takes quite a lot of effort to get the two parts of the connector to assemble; it took me quite a lot of effort.
  • Replace the cover and the 2 screws.
  • END of the Guide.