Before you begin

iFixit Soldering Guide Is your counter not working correctly on your Sony TCM-450 or TCM-450DV? Then your counter's belt may not be working correctly and this guide will help you replace it. The counter is made to mark certain points in tape.

Step 1

Repair step

  • Remove the two 3.5 mm Phillips #00 screws from the bottom of the device.
  • Caution: Ensure the device is off and unplugged if using the power adapter, as it is unsafe to remove the cabinet while on and will cause damage and potential harm to the user.
Step 2

Repair step

  • Open the lid, and carefully remove the two 9.7 mm Phillips #0 screws from the inside of the front cabinet.
  • Exercise caution while removing these screws, as damage to essential parts may occur and other minor damages may occur if the screwdriver slips.
Step 3

Repair step

  • Open the battery cover, and gently remove the back cabinet with the iFixit Opening tool.
  • The device will make a popping sound when removing the back cabinet. The back cabinet may feel as if it is not loose. However, as long as the back cabinet looks disconnected from the lid, it is safe to remove.
Step 4

Repair step

  • Carefully desolder each connection and gently remove each connected wire.
  • If you are unfamiliar with desoldering and soldering, please consult the iFixit Soldering Guide.
  • Make sure the soldering iron is 50 watts as 30-40 watt soldering irons will not melt the solder on the PCB.
Step 5

Repair step

  • Carefully desolder the next set of connections and gently remove the connected wires.
Step 6

Repair step

  • Carefully desolder the last two groups of connections and gently remove the wires.
  • Caution: Desolder all three marked connections at once before attempting to remove the wires, as they will not fully disconnect and cause damage to the device.
Step 7

Repair step

  • Carefully remove the three inner screws as shown from the circuit board to loosen it.
  • Remove the following screws in this order:
  • A 3.4 mm Phillips #00
  • A 4.6 mm Phillips #00
  • A 9.7 mm Phillips #0. To remove this screw you must lift the PCB at the same time.
Step 8

Repair step

  • Lift the PCB from the device.
  • Make sure not to pull out any wires while lifting the board, as it could cause damage to the device.
Step 9

Repair step

  • Remove the counter belt by pulling it gently out and away from the parts it connects to and away from the board.
  • Make sure that you do not pull the belt too hard, or it may snap back and hit you as it is made of rubber.