FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

Audio-Technica AT-LP120-USB Precision 500 mA Regulator Replacement

If you are having problems with your turn table...

iFixit Library Audio-Technica AT-LP120-USB Moderate 10 minutes Guide 179936
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

If you are having problems with your turn table not spinning and have not found the cause to be a problem with the power or wiring, you may have a faulty Regulator on your board that is preventing power from reaching the motor.

Step 1

Repair step

  • Use a Phillips #2 screwdriver to remove the four 2.5 mm screws.
Step 2

Repair step

  • Identify the Precision 500 mA Regulator.
  • If there is RTV Adhesive Glue, slightly pull back and forth on the Precision 500 mA Regulator to loosen the glue and break it free.
Step 3

Repair step

  • Flip the board that was loosened from removing the four screws and go on the opposite side of where the Regulator is located. Desolder the regulator.
  • Remove the faulty regulator.
  • A new regulator will need to be soldered back on.