Eaton Ellipse ECO 1200 UPS Battery Replacement

Use this guide to replace the batteries in an...

iFixit Library Eaton Ellipse ECO 1200 Easy 5 - 15 minutes Guide 181115
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

Use this guide to replace the batteries in an Eaton Ellipse ECO 1200 UPS. Before you begin, turn off the UPS and unplug it from the wall outlet.

Step 1

Unplug and power off the UPS

  • Unplug all cables from the UPS and turn it off completely.
Step 2

Remove the door screw

  • Unscrew the Phillips screw at the bottom left of the inverter.
Step 3

Opening the base battery door

  • Pull with your fingers or use a iFixit Opening Tool to start dislodging the base battery door until you feel a small click.
  • Then pull the door downward. When it is open roughly as shown in the second photo, pull it to the left to remove it completely.
  • Opening and closing the door may require significant force due to the hooks that hold it in place.
  • When opening or closing, the door may make a loud noise. Do not worry: this noise comes from the hooks shifting to allow the door to open or close.
Step 4

Remove the batteries

  • Once the door is open, remove the two batteries by pulling them downward.
  • Removing the batteries may require a little force.
  • Once the batteries are out, remove the wires to disconnect them.
  • When installing the new batteries, ensure that the polarities (+ and -) match the old batteries and that the cables are routed correctly.