Henry Hoover/Vacuum Cleaner PCB Bypass

If the high-low switch no longer works either...

iFixit Library Henry Vacuum Moderate 30 minutes Guide 181873
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

If the high-low switch no longer works either the switch or PCB needs replacing. If the motor powers up for a second when turns off and then dies it can also be a problem with the PCB. The PCBs for Henrys can be expensive and hard to source but it can be easily bypassed. This will remove the high-low function but it will still work.

Step 1

Remove head from base

  • Make sure it unplugged from the mains.
  • Pull out the black clips on each side of the head.
Step 2

Remove cable reel

  • Remove the 4 outer Phillips screws
  • Remove the cable reel from the top
Step 3

Remove cover

  • Remove the 3 inner Phillips screws
  • Remove the plastic cover
Step 4

Remove PCB

  • Pull the PCB out of its slot inside the housing
  • Remove all of the wires from the PCB
Step 5

Remove Hi-Lo Switch

  • Pull out the red High-Low switch and remove all of the wires
Step 6

Rewire On-Off Switch

  • Remove the 2 wires from the on-off switch which connected to the rest of the vacuum cleaner.
  • Connect the 2 white wires from the motor to the green on-off switch.
Step 7

Fill gap left by Hi-Lo switch

  • Place the red high-low switch back in to its holder in the casing to fill the gap and prevent potential shocks.
  • Optionally, an indicator LED can be purchased online to fill the gap.