WMF Stelio milk frother does not heat up - replace the NTC thermal sensor

This guide shows the replacement of the NTC...

iFixit Library WMF Milchaufschäumer Stelio Moderate 1 - 2 hours Guide 182305
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

This guide shows the replacement of the NTC temperature sensor on a WMF Stelio milk frother. On my device, the status indicator flashed red. The heating function failed, while cold frothing was still possible. Check the specifications and design of the replacement sensor against the original before installation. Plan for one to two hours with existing soldering experience and a suitable replacement part.

Step 1

Prepare the device and test the sensor

  • Disconnect the milk frother and its base from the power supply and let the device cool down completely.
  • Remove the three base screws from the feet with a suitable driver bit and carefully open the housing.
  • Capacitors may still be charged after unplugging. Only touch the electronics after confirming there is no voltage; follow the safety instructions for the device.
  • Disconnect the temperature sensor from the circuit before you measure its resistance with a multimeter. Only perform resistance measurements on a device that is disconnected from power.
  • In my device, the resistance of the defective sensor was approximately 600 Ω and did not change when heated. With an intact NTC, the resistance decreases as the temperature rises.
Step 2

Replace the NTC

  • Document the position and routing of the sensor and its cable before you remove the defective sensor.
  • I used an F58-100K-B3950-1% in a DO-35 housing: 100 kΩ at 25 °C, B-value 3950 K. Compare these data with the sensor specification of your device version before installation.
  • Connect the suitable replacement sensor to the sensor cable and insulate the two connection points individually. Follow the guide for connecting and insulating wires.
  • Do not reproduce switching tests with a test potentiometer on an open device being operated. Check the connections with the power supply disconnected.
Step 3

Assembly and testing

  • Reinstall the sensor to its original contact point. Replace the insulating tubing, thermal paste, and cable routing as before.
  • Close the housing completely, ensuring that no cables are pinched.
  • Perform an electrical safety test before returning the device to normal operation.
  • Check the heating and automatic shut-off with the device closed.