Before you begin

The Rowenta Turbo Silence 12” Table Fan oscillating mechanism deteriorates with time resulting in improper fan rotation along with clicking sounds and movement restrictions. This instructional guide shows you how to break apart and modify the turning mechanism until the proper turning function returns. Before You Begin: Plug off the device to guard against electrical dangers.

Step 1

Repair step

  • Unplug the fan from its outlet before beginning disassembly.
  • Use a Phillips screwdriver to loosen the screw securing the front and back grills.
  • Remove the front grill.
Step 2

Repair step

  • Remove the fan guard by turning it to the right.
Step 3

Repair step

  • Pull the the fan blades off of the fan axle.
Step 4

Repair step

  • Turn the white plastic bracket to the left and remove it.
Step 5

Repair step

  • Remove the back grill.
Step 6

Repair step

  • Remove the three 1.2 mm Phillips screws that secure the motor cover.
Step 7

Repair step

  • Remove the motor cover.
Step 8

Repair step

  • If the fan is too loose or wobbling, tighten the screw to secure the movement.
  • If the fan is stuck and not turning, loosen the screw slightly to free up the mechanism.
  • Test the fan after adjusting to ensure smooth movement.
Step 9

Repair step

  • Check the side screw for any necessary adjustments and tighten if it's loose.