Prusa CORE One Nozzle Replacement

The following guide is based on information and...

iFixit Library Prusa CORE One Easy No estimate Guide 182464
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

The following guide is based on information and photographs from Prusa's Official Nozzle Replacment Guide. The information on this guide can be used with all Prusa Nozzle diameters. Background Information Normally, you’ll need to replace your nozzle if you notice a decline in print quality. For preventive maintenance, brass nozzles should be replaced every 3 to 6 months. Hardened steel nozzles can last longer (up to 12 months) and ruby-tipped nozzles several years. Prusa claims that their brass nozzles can withstand 2800 meters (9,186 feet 4.22 inches) of filament or 2400 hours of printing. This lifespan can vary depending on the frequency of use of your 3D printer and the quality of the filament.

Step 1

Preparing your CORE One

  • Close the printer's door.
  • Unload the filament via the printers Unload filament feature.
  • Remove the filament spool from the printer
  • Cool down the printer by navigating to Preheat, then Cooldown, and wait for the temprature to drop to the ambient temperature.
  • Ensure that the printer has cooled down completely before continuing.
Step 2

Printer Preperation Continued

  • Set your Z-Axis to 100 mm or more by going to Control, Move Axis then Move Z
  • Allow your printer's heatbed to move
  • Once the heatbed has finished moving, turn your printer off using the power switch on the back of the printer.
  • Remove the power cord from the printer to prevent the printer from being powered on accedently.
Step 3

Removing the Top Cover

  • Remove the Top Cover of the printer by pushing the nylon rivets from the inside.
  • Once pushed out, the rivets can be removed from the outside.
  • Remove all the rivets using the same method detailed above.
  • Once all the rivits have been removed, the top cover of the printer can be removed.
Step 4

Protecting your Heatbed

  • Cover your Heatbed with a piece of cloth, or other thick material.
  • This is to prevent your Heatbed from being damaged in the event your Hotend assembly is dropped during the dissassembly process.
Step 5

Removing Nextruder Undercovering

  • Remove the two M3x10 screws holding the side over to the assembly.
  • Once the screws are removed, take the cover off your assembly.
Step 6

Disconnecting Hotend Cables

  • Disconnect the cable for the Hotend Heater
  • Disconnect the cable for the Hotend Thermistor.
  • Each cable features a safety latch that holds each cable in its place. Be sure to press the latch before disconnecting to keep from damaging the connector.
Step 7

Removing the Hotend Assembly

  • Carefully unrout the disconnected hotend cables from the cable guide.
  • Grasp the Hotend with one hand.
  • With your free hand, loosen the two thumb screws holding the Hotend in place. Removing the thumb screws is not nessessary. A few turns is enough to get the Hotend free.
  • The Hotend will fall out if not held properly. Be sure you have your cloth protecting your Headbed.
  • Carefully slide the Hotend assembly out of the Heatsink.
Step 8

Removing the Nozzle

  • Remove the protective silicone sock from the heater block.
  • Use the 13 mm wrench to hold the heater block.
  • Use the 7 mm wrench to grasp and loosen the nozzle from the heater block.
  • Once loosened you can manually unscrew, and slide the nozzle out from the heater block.