Arlo Pro 2 Camera Micro-USB Port Replacement

If your Arlo Pro 2 camera is not charging,...

iFixit Library Arlo Pro 2 Moderate 10 - 15 minutes Guide 185703
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

If your Arlo Pro 2 camera is not charging, follow this guide to walk you through the steps of replacing the Micro-USB charging port in your Arlo camera. The Arlo Pro 2 battery usually last between 3 to 6 months on average. When battery has depleted the camera will no longer send motion captures to the connected device. Make sure to inspect the USB port for any dirt or debris that may interfere with the connection. Before starting this guide ensure that the camera is disconnected from any external power source.

Step 1

Repair step

  • Press the release button on the camera and gently pull apart the casing to open the device.
  • Remove the battery from inside the case.
Step 2

Repair step

  • Use a T5 Torx screwdriver to remove the four 7 mm screws securing the camera case.
  • Carefully pull the outside of the case apart from the internal case to remove the camera components from the outside casing.
Step 3

Repair step

  • Use a Phillips #00 screwdriver to remove four 4 mm screws connecting the daughterboards to the motherboard.
  • Seperate the daughterboards from the motherboard and camera casing.
Step 4

Repair step

  • Use a Flathead 4 mm screwdriver to remove the four 7 mm screw posts connecting the motherboard to the case.
  • Carefully pull the motherboard apart from the camera casing.
Step 5

Repair step

  • Disconnect the white cord from the port on the motherboard, by gently pulling away from the port to fully isolate the motherboard from the case.
Step 6

Repair step

  • Thread the wires of the Micro-USB port through the casing.
  • Guide the wiring through the opening so that the wiring is solely in the battery cavity and not going through any part of the case.
Step 7

Repair step

  • Use a Phillips #00 screwdriver to remove two 3 mm screws connecting the Micro-USB port to the camera casing.
  • Gently remove the Micro-USB port by pulling it away from the case.