FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

Electric Water Heater

What you need to know about this product: (1)...

iFixit Library Termotanque Eléctrico Rheem Aee Tep085rh Negro 85l Mm Moderate 2 hours Guide 187010
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

What you need to know about this product Voltage: 220VElectric ignition.Power: 2000W.Top water connection.Designed for floor-standing installation.Includes a safety valve for your and your family's peace of mind.Weight: 26 kg.Easy to install.Ideal for heating and maintaining a specific volume of water.Dimensions Width x Height51 cm x 91 cmDiameter51 cmCommon problems.Sacrificial Anode Where is the magnesium anode in a Rheem water heater?Your Rheem water heater's anode rod is located at the top of the tank. Specifically, your magnesium or aluminum sacrificial anode is visible through a hexagonal head located at the center of your water heater under a plastic cover. It should be replaced annually, depending on the water quality with or without filters.2000W resistance.In many cases, when the residual-current device in the electrical panel trips, the problem is a leak and/or crack in the resistance. To change the part, you need a pipe wrench and a wrench for resistances. You must ensure it has the same capacity (2000W) and brand (in this case, Rheem), as many water heaters have the anode and resistance combined. A thermostat that controls the hot water temperature. The thermostat is adjusted to regulate the desired temperature and, once reached, cuts off the electrical power to the resistance, preventing the water from overheating. To know if an electric water heater's thermostat is broken, you can check if the water does not heat correctly, if there are temperature fluctuations, or if the pilot light does not turn on when resetting. You can also use a multimeter to check the thermostat's electrical continuity. Checking with a multimeter (requires basic electrical knowledge):Disconnect the power: Before starting, make sure to disconnect the electrical power to the water heater.Locate the thermostat: The thermostat is usually located at the bottom of the water heater.Select the ohms scale: On the multimeter, select the ohms scale.Perform the tests:Continuity in the main thermostat: If there is continuity between the main thermostat terminals when the water heater is off, this indicates that the thermostat is closed and working. If there is no continuity, the thermostat may be broken, according to John Owens Services.Safety thermostat: The safety thermostat must be open when the water heater is off and closed when the water temperature reaches the set point.Interpret the results: If the multimeter shows incorrect values, the thermostat may be failing.

The iFixit procedure is temporarily unavailable through the API.

You can still open the attributed original source safely.

Open the authorised source