Step 1

Repair step

  • Once the basic checks have been performed, as seen in other guides in this series, we are going to look at how to repair, or attempt to repair, the following fault: "Broken Nichrome wire."
  • 1st Teardown of the power lever; carefully pry it off with a screwdriver or a round-tipped knife.
Step 2

Repair step

  • 2nd. The time adjustment knob is also removed by prying it off.
  • 3rd. Remove the 4 screws from the bottom case.
Step 3

Repair step

  • With the casing removed, here are the views of the interior.
  • Photo 1: General view.
  • Photo 2: Detail of the contact points or ignition contacts of the machine; these also cause problems, I will talk more about them later.
  • Photo 3: View of the electronic board or PCB.
Step 4

Repair step

  • These are the points where we need to check continuity with a multimeter: the input cable to the Nichrome wire, the output on the opposite side, the connection to the next central wire plate, the output from this one, and its connection to the next; it's simply 4 wire runs connected in series, the same as if they were 4 resistances connected in series.
  • Photo 1: We can see the input on the top left, and the 2 outputs on the right side (the center is an intermediate output) and the one on the bottom right is the Nichrome wire output.
  • Photo 2: We can see an exploded view of the outputs on the right side, the intermediate tap, and the output at the bottom.
  • Photo 3: View of the connections between Nichrome wire plates.
Step 5

Repair step

  • Start of the check: Set the multimeter to the ohms scale as explained in Guide 4:
  • We will place one of the test leads on the power input to the Nichrome wire.
  • With the other test lead, we will check the output of the wire towards the next board, on the back.
  • Photo 3: Seeing that the first run of Nichrome wire no longer showed electrical continuity, I move on to check the second one, between the bottom and the top.
Step 6

Repair step

  • Photo 1: Ohms measurement of the intermediate plate, corresponding to the test performed in Photo 3 of step 5. "Plate OK".
  • Photo 2: Measurement of the 3rd plate's nichrome, measured between the top and the intermediate output tap, "Plate OK".
  • Photo 3: Measurement of the 3rd plate's nichrome, measured between the top and the bottom output tap, "Plate OK".
  • Having seen this, we have found the break in the first plate measured in step 5.
Step 7

Repair step

  • We visually inspect the board and observe in this case the deformed Nichrome wire and the cracked mica board.
Step 8

Repair step

  • The following step involves removing the sides and the top stainless steel plate or trim to be able to access the MICA plate.
  • Unhook the interior separator wires and remove the top stainless steel trim.
Step 9

Repair step

  • We now have access to the broken MICA support plate and can see the cut Nichrome wire or filament.
Step 10

Repair step

  • As I explain in another document: the Nichrome wire can be repaired using 1 small screw, a nut, and 2 washers.
  • Join the 2 plates in their correct position at the height of the break, and carefully drill a hole with a screwdriver or an awl.
  • Insert the screw + washer from the outside. Place the 2 ends of the Nichrome wire next to the screw so they are pressed by the washer to be installed. On the inside, place the washer + nut. Carefully tighten the screw and nut.
Step 11

Repair step

  • In the exploded view, apply 2 small drops of superglue to the broken mica plate. BE CAREFUL not to use too much; only apply a few small drops.
  • Although it would not matter if you did, since there is space between the mica sheet and the Nichrome wire, the screw head, and the metal housing, I usually place a small piece of adhesive felt as an insulator for safety, trimming it as tightly and "small" as possible.
Step 12

Repair step

  • Install the protective felt pad to prevent potential shorts or accidental electrical connections due to proximity.
Step 13

Repair step

  • Follow these instructions in reverse order to reassemble your device.
Step 14

Repair step

  • Reinstall the metal side cover and the inner spacer wires, and perform a continuity test on the Nichrome wire; where it previously gave no reading, it now shows a reading in ohms.
Step 15

Repair step

  • Exploded views showing where we take the verification measurement to confirm the repair has been successful.
Step 16

Repair step

  • Reassemble the stainless steel top case.
Step 17

Repair step

  • With the whole assembly put together, we perform a resistance test of the entire length of the Nichrome wire, measuring directly at the power plug.
Step 18

Repair step

  • As we can see, the total resistance of the Nichrome circuit is around 60 ohms in machines powered by 230 V.
Step 19

Repair step

  • View of the machine operating, locked in place, and heating the Nichrome wire.
  • Other guides in this series:
  • EXPLANATORY VIDEO:
Step 20

Repair step

  • Annex to the repair guide, video explaining other typical toaster failures.
  • - Breakage of the Nichrome wire, explained in this guide.
  • - Input contact points, scorched or burned; they can be cleaned with sandpaper or a nail file.
  • - Interlock electromagnet coil cut or burned, (this failure is not usually common and unfortunately is not usually repairable).
  • - Resistance of approximately 100 ohms for the power supply to the interlock coil burned; it can be measured, checked, and replaced.