Repair step
- This document is only for general informational purposes, so we can distinguish what we see inside the machine.
- Photo 1: Green arrow, water pump; Yellow arrow, flow meter; Blue arrow, water inlet to the machine. It must NEVER be dry; if it has ever been dried out due to transport, we must refill it with water before placing the tank on top.
- Photo 2: Water pump connectors; remember that the pump has a thermal fuse installed. In this machine, test the pump coil or power it directly with an external cable to perform tests.
- Photo 3: Power input cables that go up to the electronic board, which always receives mains voltage.