Step 1

Remove film advance lever

  • Remove the rubber decorative cap. It is attached with contact cement underneath. Isopropyl Alcohol may be used to soften the adhesive.
  • Unscrew the lock nut using a spanner wrench. The lock nut is reverse threaded.
  • Lift off the advance lever.
  • Remove the spring washer.
  • Remove one shim washer.
Step 2

Remove mode dial

  • Set the mode dial to the 'L' position.
  • Use a spanner wrench to unscrew the dial lock nut.
  • Lift off the mode dial.
Step 3

Remove exposure compensation dial

  • Place a rigid object in the fork.
  • Unscrew the rewind lever.
  • Use a spanner wrench to remove the lock nut.
  • Lift off the exposure compensation dial.
Step 4

Remove top cover screws

  • Remove two screws on either side of the eye piece.
  • Remove two screws on either side of the lens mount.
Step 5

Remove top cover

  • Remove one screw by the exposure compensation dial.
  • Use a spanner wrench to remove the lock nut under the advance lever.
  • Lift off the top cover slowly. It is still attached by one wire.
  • Unsolder one gray flash sync wire.
Step 6

Remove bottom cover

  • Remove three M1.7 x 3 mm screws.
  • Remove bottom cover.
Step 7

Remove front leatherette panels

  • Use a nickel or other large coin to remove the hand grip.
  • Drip isopropyl alcohol along the edge of the leatherette to soften the adhesive.
  • Use a dull scraper to lift one corner and pull off the panel.
  • Repeat on the rewind side of the camera.
  • Installation Notes: Use contact cement to reattach the leatherette after the camera has been fully reassembled and tested.
Step 8

Detach flex PCB with adjustment pots

  • Remove one M1.7 x 4.5 mm screw.
  • Remove one slotted screw.
  • Use isopropyl alcohol to soften the adhesive under the flex PCB.
  • Gently lift the PCB until it is free from the camera body.
Step 9

Unsolder motor drive connections

  • Unsolder red wire for positive battery.
  • Unsolder green wire.
  • Unsolder orange wire for motor drive shutter release.
  • Unsolder purple wire for wind completion switch.
Step 10

Remove tripod mount

  • Remove one M1.7 x 4.5 mm screw.
  • Remove one M1.7 x 5 mm screw.
  • Remove one countersunk M1.7 x 5.5 mm screw.
  • Lift the contact terminal free from its seat.
  • Remove the tripod mount.
Step 11

Detach ISO resistor assembly

  • Remove one slotted screw.
  • Remove one M1.7 x 4 mm screw.
  • Loosen one slotted screw (this will remain connected to the assembly).
  • Lift the ISO resistor assembly off the rewind post. It is still attached by a flex PCB.
Step 12

Detach mode dial unit

  • Remove one M1.7 x 2.5 mm screw. It is only accessible when the mode dial is in the 'L' position.
  • Lift the LCD out of the way. It is still attached by a flex PCB.
  • Remove one M1.7 x 2.5 mm screw.
  • Remove one slotted post.
Step 13

Unsolder flash sync wires

  • Unsolder two gray wires.
Step 14

Unsolder shutter wires

  • Unsolder white wire.
  • Unsolder brown wire.
  • Unsolder red wire.
Step 15

Unscrew mirror box

  • Remove two M1.7 x 2.5 mm screws.
  • Remove one M1.7 x 3.5 mm screw under the bottom plate.
  • Some versions of the camera may have an additional screw under the tripod mount that needs to be removed.
Step 16

Unscrew front board

  • Wind the advance lever to put the shutter and mirror box in the charged state.
  • Remove four M1.9 x 5 mm screws.
Step 17

Remove mirror box and front board

  • Make sure the mode dial unit and ISO selector unit are free from their mounting points.
  • Wiggle the mirror box and front board free.
  • Watch for wire snags as you pull it free.
  • Check for loose shim washers on the front board and note their position.
Step 18

Installation Notes: Front Block

  • Shutter should be in the charged state.
  • Mirror box should be in released state.
  • Pay close attention to wire routing during install.
  • To test the actuation of the mirror and shutter, wind the camera, then insert a tool into this slot and push the release lever to the left.
Step 19

Unsolder Main PCB

  • Unsolder one orange and one blue wire for the mirror release solenoid.
  • Unsolder one pink wire for the LCD backlight.
  • Unsolder two purple wires for the TL switch.
  • Unsolder one green wire for the MD switch.
Step 20

Unsolder lens mount connections (early production)

  • Unsolder six wires for the lens mount pin connections.
  • These are only present on the early production models. Later production models moved these connection points to the flex connector.
Step 21

Unsolder aperture resistor

  • Unsolder two yellow wires for the aperture resistor.
Step 22

Unsolder eye piece

  • Unsolder the red and black wires for the metering cells in the eye piece.
  • Unsolder pink and green wires for the flash sync connections.
Step 23

Unsolder front board connections (early production)

  • Unsolder blue and black wires for self-timer LED.
  • Unsolder orange wire for beeper.
  • Unsolder gray and pink wires for aperture solenoid.
  • Unsolder light blue and yellow wires for aperture optical encoder.
  • Unsolder purple wire for self-timer contact.
  • Remove one screw.
Step 24

Detach flex PCB connection (late production)

  • Remove two M1.4 x 2 mm screws.
  • Use a spudger to gently pry off the connector plate.
  • Remove the silicone insulating pad.
Step 25

Detach viewfinder LCD

  • Remove two M1.4 x 1.6 mm screws.
  • Look for shim washers when removing and note their position.
Step 26

Remove mirror governor

  • Remove one M1.7 x 4.5 mm screw.
  • Loosen one M1.7 x 4.5 mm screw but leave it in place.
  • Remove two M1.7 x 1.6 mm screws.
  • Remove the mirror governor.
  • Remove one plastic bushing.
Step 27

Remove main PCB

  • Gently lift away the PCB from the mirror box.
  • The TTL flash metering cell needs to be unseated from the side of the mirror box to free the PCB for removal.