Step 1

Repair step

  • Once disassembled, diagnosed, and the problem located as I explain in guides 1 and 2 NESPRESSO AEROCCINO 3694, in this guide I proceed to replace the motor (the faulty component in the milk frother), a task that is relatively simple.
  • Extract the magnet by pulling on it and prying. Remove the 2 Torx screws from the plastic motor support housing, lift it, and place the housing to the side.
Step 2

Repair step

  • I purchased the replacement on AliExpress; there are many sellers, it is a very common motor.
  • For motor model 500TB-12560, we must make sure when ordering that the replacement matches the number of machine screw holes, the height measurement, and the shape of the base.
  • I am noting the description of the one I bought; I am not providing a link since sellers are constantly appearing and disappearing, and it would end up as a broken link.
  • Mabuchi RF500TB-12560 DC motor, 1.5V, 6V, 12V, 4600 RPM, 32 mm, for spray machine
Step 3

Repair step

  • Before installing the replacement, we will check that it is identical.
  • The position of the + and - wires is not marked on the plastic housing; I used the faulty motor as a guide, looking at the position of the 3 screw holes on the top.
Step 4

Repair step

  • Once the red and black wires are soldered to the motor, we can proceed to insert it into the compartment; CAUTION, it has a specific orientation, so we must insert and position it carefully.
  • Replace the plastic housing and fasten the 2 screws.
Step 5

Repair step

  • Verify that the motor is correctly and fully inserted into the plastic guides on the base; if it is not, you will not be able to install the clear plastic cover.
  • Install the clear plastic cover.
Step 6

Repair step

  • Once the cover is inserted, secure the 2 side screws.
Step 7

Repair step

  • With the motor now secured, replace the magnet on the motor shaft, tightening it carefully.
Step 8

Repair step

  • Check with your finger that the motor shaft rotates and does not get stuck at any point, then insert the assembly into the housing.
Step 9

Repair step

  • With the two side L-brackets that hold the assembly in place closed, look at the base of the pitcher. The assembly must be inserted in a specific position; check the orientation of the two power terminals and the motor circuit, marked with a yellow arrow in the photos.
  • Once you have observed the correct position, carefully insert the assembly.
Step 10

Repair step

  • Insert the 2 securing screws and use tweezers to position the plastic button guide.
Step 11

Repair step

  • Place the button and press it into place until it clicks.
Step 12

Repair step

  • We will test the machine, both the hot blender function and the cold blender function. Red, Spins and Heats.
Step 13

Repair step

  • Works correctly, Blue, Spins without heating, fault fixed.