Guide overview

Before you begin

This guide covers the complete disassembly of the steamer. The thermal insulation is replaced. Also visible and replaceable: Fan rollerPotentiometerDisplay moduleDoor switchLampPower electronicsetc.

Step 1

Remove and prepare the steamer

  • Open the door and release 2 screws
  • Pull the steamer out and place it on a pedestal
  • Unplug the power cable
Step 2

Repair step

  • Place the steamer in a free-standing location
  • Place on a pedestal for good accessibility
  • Torx T20 for all screws
Step 3

Repair step

  • Remove the 4 screws
  • Remove the cover
Step 4

Repair step

  • Release 1x screw on the fan roller
  • Remove the bracket
  • Remove the wires
  • Press the small tab to release the cable lug
Step 5

Repair step

  • Carefully pull the multi-pin cable out of the display module
  • Carefully pull the door switch cable out
  • Unthread the pulled-out cables and set them aside
Step 6

Removing the power module

  • Slightly press the tabs outward
  • Lift the power module out of its holder
  • Pack the power module in a plastic bag to protect it against mechanical and electrical damage
Step 7

Repair step

  • Remove 6x screws
  • Remove the housing back cover
Step 8

Repair step

  • Release 1x screw on the grounding
  • Release the cable from the cable holder
  • Place the wrapped power module downwards
Step 9

Removing the display assembly

  • Move the cables to the side
  • Pull the display assembly upward
  • If necessary, gently pry up the tabs on the sides
  • Continue without display assembly removal -> Step 14
Step 10

Repair step

  • Place the display module on a clean, flat surface
  • Gently squeeze the potentiometer and pull it out of its housing
Step 11

Repair step

  • Rotate the mounts 90° counter-clockwise
  • Pull out carefully
  • Do not pull or pry with excessive force when pulling out
Step 12

Repair step

  • Remove 2x screws
  • Press 3x levers
  • Pull out the display module
  • It is held firmly on the left side. If necessary, use a screwdriver to gently pry it out
Step 13

Repair step

  • Reattach and click the display assembly into place
  • Reinstall the two screws
Step 14

Repair step

  • Reinsert and screw in the mounts
  • Both (2) tabs must be properly hooked in when screwing in
  • Click the potentiometer into place
  • The knob must be properly aligned
Step 15

Repair step

  • Release the 6x screws
  • Remove the ventilation cover
Step 16

Repair step

  • 2x release screws
  • Remove steel plate
  • 4x release nuts
  • Remove flap
  • (X) Mark metal parts, note orientation
Step 17

Repair step

  • Release 4x screws (2 on each side)
  • Remove the housing top
Step 18

Repair step

  • Remove 1x screw from the bottom
  • Remove 7x screws from the side
  • Remove the side panel and rail
Step 19

Repair step

  • Remove 1x bottom screw
  • Remove 7x side screws
  • Remove the side panel and rail
Step 20

Repair step

  • Bend the wire ends upward
  • Pull the wire out of the eyelet and remove it
Step 21

Repair step

  • Pull out the connection cable
  • Remove the cable connection with 2x screws
Step 22

Repair step

  • Remove the 2 screws from the bottom front
  • Remove the drainage channel
Step 23

Repair step

  • Tilt the upper steamer part and rest it on the door
  • Use a clean and soft surface
Step 24

Repair step

  • Remove old thermal insulation
  • Clean everything of residue and small flakes
  • Gloves and long clothing are recommended
Step 25

Repair step

  • Unplug the hose from the tray
  • Unplug the cable from the tray
Step 26

Repair step

  • Insert new thermal insulation
  • Cut out the casing
  • Cut out the exhaust vent
Step 27

Repair step

  • Unplug the cable from the lamp
  • Cut out the thermal insulation
  • Place the thermal insulation over the lamp
  • Reconnect the lamp
Step 28

Repair step

  • Reattach the hose to the shell
  • Reconnect the cable to the shell
Step 29

Repair step

  • Place the drain channel onto the bottom housing
  • Secure with adhesive tape
Step 30

Repair step

  • Place the upper steamer part onto the lower housing
  • Install the drain channel with 2 screws
Step 31

Repair step

  • Insert the wire for thermal insulation at the bottom
  • Wrap it around the thermal insulation
  • Guide it through the eyelet and tighten
  • Make sure no cables are pinched!
Step 32

Repair step

  • Insert the side panel and rail
  • Secure everything with 7 screws
  • Secure the bottom with 1 screw
Step 33

Repair step

  • Insert the side panel and rail
  • Secure everything with 7x screws
  • Secure the bottom with 1x screw
Step 34

Repair step

  • Assemble the housing upper part
  • Place one metal plate under and one metal plate over the front cover
Step 35

Repair step

  • Hook the upper housing section securely onto the housing side panels
  • Secure with 4x screws
Step 36

Repair step

  • Align the upper metal plate with the cutout
  • Push the thermal insulation to the side
  • The sealing surface and threads must be free of insulation
Step 37

Repair step

  • Place the flap on the cutout
  • Press the flap down until the threads come out of the holes
  • Secure everything with 4 nuts
Step 38

Repair step

  • Place the plate on
  • Secure with 2x screws
Step 39

Repair step

  • Screw on the ventilation duct with 6 screws
Step 40

Repair step

  • Slide the power module into the mount
  • and snap it into place
  • Plug in the door switch
  • Thread the cable
Step 41

Repair step

  • Connect grounding
Step 42

Repair step

  • Secure the cable connector with 2 screws
  • Insert the connection cable into the cable grommet
Step 43

Repair step

  • Attach the housing rear cover
  • Secure with 6 screws
Step 44

Repair step

  • Slide the fan roller into the fan duct
  • Watch for the metal tabs
  • Install the bracket and secure it with 1x screw
  • Attach the cable lugs
Step 45

Repair step

  • Hook in the display assembly
  • Snap it into place on both sides
  • Connect the display multi-pin cable
  • Connect the potentiometer multi-pin cable
Step 46

Repair step

  • Slide the cover off
  • Secure with 4 screws
Step 47

Repair step

  • Steamer fully assembled
  • Place the steamer on a raised platform in front of the niche
  • Plug in the steamer's power cable
  • Slide it into the niche until it stops
Step 48

Repair step

  • Fasten the steamer
  • Test the steamer