Apple Studio Display M2454 LCD Main Board Replacement

The LCD main board is the backbone of the Apple...

iFixit Library Apple Studio Display M2454 Easy 20 minutes Guide 1966
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

The LCD main board is the backbone of the Apple Studio Display M2454. It accepts the information coming from the computer and transmits this data to the screen to form an image. The main board is also wired into the USB ports on the back of the monitor and other circuitry. There are many connections but replacing this board is relatively easy.

Step 1

Repair step

  • Locate the four hex head screws located on the corners of the back panel.
  • Remove the screws with a 2mm hex screwdriver.
Step 2

Repair step

  • Locate the three 2mm hex screws located on the back stand of the monitor.
  • These screws must be removed with the 2mm hex screwdriver in order for the back panel to be removed.
Step 3

Repair step

  • Pull the clear back panel cover off.
  • Be sure to feed the cable through the back panel so no damage occurs.
Step 4

Repair step

  • Now remove the back panel under the clear cover.
  • Again, feed the cable through the panel so no damage occurs.
Step 5

Repair step

  • Remove the phillips head screw holding the back panel spacer with the phillips head screwdriver.
Step 6

Repair step

  • Remove the two phillips head screws near the cable attachment with the phillips head screwdriver.
Step 7

Repair step

  • To remove the metal plate covering the circuitry you need to push the cover towards the base of the monitor. (First remove any transparent plastic piece on the two USB connectors.)
  • If done correctly the tabs holding the plate should be detached and the plate will easily pop off.
Step 8

Repair step

  • Now that the circuitry is exposed the boards can be seen and replaced.
  • The LCD Main Board is the largest board in the center of the device with seven external connections.
Step 9

Repair step

  • Locate the four phillips head screws on the corners of the board.
  • Using the phillips head screwdriver, remove the four screws holding the board to the monitor.
Step 10

Repair step

  • Remove the four braided connections simply by pushing the side of the connectors in and pull out.
Step 11

Repair step

  • Remove the other two connectors by raising the tab on each either by hand or using a flat ended tool as shown.
  • Then gently pull away from the board to release tabs.
  • The tabs can easily break off, be extra careful.
Step 12

Repair step

  • Remove the final black connector by pressing down on the back of the tab on the connector and then pull away from the board.
  • Be careful when holding onto the board while removing this connector or you risk pulling the board away too quickly and damaging the connector.
Step 13

Repair step

  • With all the connectors removed the board can be lifted away.