Step 1

Repair step

  • Having located the problem in the diode bridge and the power input fuse as I explained in Guide 2, I am proceeding to replace them.
  • We will need an electronics soldering iron of approx. 40 W, solder, a desoldering pump, and a flathead screwdriver for prying.
Step 2

Repair step

  • Before removing the diode bridge, apply a little more solder so the joints heat up properly and it can be removed more easily.
  • To remove it, heat 2 solder joints while applying slight leverage; for some, you can use a solder sucker (which absorbs the hot solder).
Step 3

Repair step

  • Once the diode bridge is removed, we test it outside the PCB and observe that at the AC input it already shows resistance when polarized in both directions (- /+) and (+ / -), which should not be the case in either direction.
Step 4

Repair step

  • We performed other checks between pins, noting that it also shows resistance; the diode bridge is internally burned, even though it shows no external deformation or visible spots where any problem can be seen.
Step 5

Repair step

  • Since you do not have the same diode bridge as a replacement, look in the recycling bin for a similar bridge in terms of size and pinout location, as you can see in photo 1, the pinout position varies from one bridge to another.
Step 6

Repair step

  • As this is teardown material recycled from other devices, I check the chosen component with a multimeter in ohms before installing it on the PCB; it is correct and can be inserted into the PCB.
Step 7

Repair step

  • Jumper (wire) inserted, soldering completed, and excess terminals trimmed.
Step 8

Repair step

  • Now it is the turn of the fuse; it must be removed and its amperage value checked on the casing.
Step 9

Repair step

  • The removed one is 3.15 Amps; since I don't have one with the wires already included, I'll find a standard 3.15 A one, solder 2 pieces of wire onto it, and cover it in heat-shrink tubing.
Step 10

Repair step

  • Soldering process for the 2 cable pieces.
Step 11

Repair step

  • Photo 1: Fuse with the wires already soldered and the red heat-shrink tubing inserted, ready to be heated and shrunk.
  • Photo 2: Heating the red heat-shrink tubing.
  • View of the PCB with the fuse already soldered to it.
Step 12

Repair step

  • Views of the inline fuse already placed on the PCB with its heat shrink tubing insulation.
  • View of the 2 damaged components; the short circuit in the bridge rectifier caused the protective fuse to blow.
  • You can find all documents in this series at: Batidora MANDINE MHB1200-20
  • END of Guide 3.