Kaffelogic Nano 7/LINK (A/B/C-N Serial) Roast Chamber Replacement

Replacement of the roast chamber on any...

iFixit Library Kaffelogic Coffee Roaster Moderate 10 minutes Guide 197218
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

Replacement of the roast chamber on any Kaffelogic Nano or Nucleus Link coffee roaster with an A, B, C or N prefix serial number.

Step 1

Removing Panel Screws

  • Unplug the roaster from mains power before proceeding. Do not perform any of these steps on a live/powered unit.
  • Remove the 6x 2.5mm Hex screws on the left and right side of the roaster.
Step 2

Lift the closure

  • Hold the roaster steady while removing the plastic top/closure.
  • Panels may spring apart slightly once removed.
Step 3

Remove bottom panel screws

  • Remove the 4x 2.5mm Hex screws on the bottom of the roaster.
Step 4

Remove the front panel

  • Pull away the front panel carefully.
  • Take care not to damage the buttons while maneuvering the front panel.
Step 5

Remove rear panel

  • Stand the roaster up again and pull away the rear panel from the chassis to expose the remaining components.
  • The mains cable is routed through the panel and it will remain attached, place the panel in a soft bag if you wish to protect the paint throughout the rest of your repairs.
Step 6

Disconnect the thermocouple

  • Use a 2.0mm slotted screwdriver to remove the thermocouple wires from the PCB-A
Step 7

White thermocouple connector

  • If your thermocouple connector looks like this, you will need to follow this step.
  • Use the end of a cable tie or very small plastic spudger to open the contact and remove/insert your thermocouple wires. You may need to trim the cable tie end to fit into the slot.
Step 8

Disconnect the roast chamber earth

  • Use a PH2 screwdriver and adjustable crescent (or 5.5mm wrench) to remove the screw holding the earth leads to the element chamber.
Step 9

Remove the roast chamber

  • Lift the roast chamber upwards, some wiggling may be required.
  • Head through to our wiki for instructions on recalibrating your fan speed after this repair.
  • Nucleus Link anemometer calibration instructions can be found here.