Step 1

Removing Panel Screws

  • Unplug the roaster from mains power before proceeding. Do not perform any of these steps on a live/powered unit.
  • Remove the 6x 2.5mm Hex screws on the left and right side of the roaster.
Step 2

Lift the closure

  • Hold the roaster steady while removing the plastic top/closure.
  • Panels may spring apart slightly once removed.
Step 3

Remove bottom panel screws

  • Remove the 4x 2.5mm Hex screws on the bottom of the roaster.
Step 4

Remove the front panel

  • Pull away the front panel carefully.
  • Take care not to damage the buttons while maneuvering the front panel.
Step 5

Remove rear panel

  • Stand the roaster up again and pull away the rear panel from the chassis to expose the remaining components.
  • The mains cable is routed through the panel and it will remain attached, place the panel in a soft bag if you wish to protect the paint throughout the rest of your repairs.
Step 6

Remove element chamber screws

  • Remove the 4x PH1 element chamber screws from the plastic bowl. (One screw not pictured)
  • When reassembling make sure there is no airgap indicated by the red and blue arrow
Step 7

Remove roast chamber

  • Set the roast chamber aside but do not disconnect any wires.
Step 8

Remove the element chamber

  • Lift the element chamber up carefully to expose the element. Set this aside.
Step 9

Remove support ring

  • Lift up the element slightly and remove the support ring.
  • Do not touch the element coil directly. Skin oils can create hotspots on the wire.
Step 10

Disconnect the element

  • Use a flathead screwdriver to remove the element leads from the terminal block.
Step 11

Remove the element

  • Pull the element leads through the fibreglass tubing to remove the element.
Step 12

Checking the connections

  • Double check the cable position, so that the screw is coming down on the wire and not the insulation of the element.