FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

Rondostat HR20: fix erratic values of adjustment dial

The adjustment dial of Honeywell Rondostat HR20...

iFixit Library Honeywell Rondostat HR20 (Style) Easy 5 minutes Guide 197423
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

The adjustment dial of Honeywell Rondostat HR20 electronic radiator controller is used to adjust temperature values and to set up times and dates. Aging devices start to show erratic behavior while using the adjustment dial - values on the display seem to jump randomly instead of being continuously incremented or decremented (depending on direction of rotation of the dial). This problem can be fixed quite easily with this guide. This guide applies to both the classic Rondostat HR20 as well as to the Rondostat HR20 "style" version. Both device variants differ in design of the housing only. Weitere Quellen: https://www.mikrocontroller.net/topic/44...https://www.mikrocontroller.net/articles...

Step 1

Removing the adjustment dial

  • The adjustment dial can be removed with cautious use of a slot screwdriver. For this purpose insert the tip of the screwdriver into the gap between the dial and the body and then carefully apply some force until the gap has opened considerably. Then use your fingers or an opening tool to push the dial out of its mounting.
Step 2

Repairing the rotary encoder

  • The root cause for the erroneous behavior of the adjustment dial is the rotary encoder, which is hidden behind a small cogwheel. This cogwheel is only plugged into the encoder and can be simply removed with two fingers.
  • With the cogwheel removed the rotary encoder is now accessible. Apply a small amount of oxide dissolving contact cleaner, then re-install the cogwheel and turn the cogwheel a couple of times in both directions using your fingers.
  • Optionally check the readings on the display (with batteries installed) to ensure that all settings can be adjusted again as intended.