ARINSAL Jigsaw, dead, does not turn on. Damaged switch.

Attributed iFixit repair guide for Sierra de Calar ARINSAL.

iFixit Library Sierra de Calar ARINSAL Easy 1 hour Guide 198078
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Step 1

Repair step

  • The ARINSAL jigsaw came to me after a failed repair attempt; the power input cable was cut and the motor brushes were displaced and incorrectly installed.
  • I replaced the cable and repositioned the motor brushes, but it still showed no signs of attempting to spin.
Step 2

Repair step

  • The motor brushes (another typical issue for this type of motor) were making perfect contact.
Step 3

Repair step

  • While performing checks, I had 230 V at the switch input, but upon pressing it, there was no voltage at the output. I removed the cover of the double switch, observing that one of the 2 circuits (by performing continuity measurements with a multimeter set to ohms, I saw which of the 2 wires it corresponded to).
  • The 2 connections of the moving part that closes the circuit are scorched, toasted, and singed. Upon removing the cover, an area with signs of excessive temperature was already visible on the inside. I trimmed and sanded the damaged part of the cover.
  • I have placed a piece of blue electrical tape so that when removing the cover and handling the assembly, the other contact + spring and a tiny steel ball that it carries in the center do not fly out.
Step 4

Repair step

  • Photo 1 view of the switch with the contact removed.
  • Photo 2 view of the contact; the two side circles that made the contact were completely scorched and even deformed. I had to thoroughly clean it with fine sandpaper to remove all the burnt material, and slightly bend and curve the contact so it would perform its function again.
  • Photo 2 you can even see the remains of melted plastic in the center of the part in the photo.
  • Photo 3 view of the repaired contact now reinstalled. Continuity between input and output checked with the multimeter; it now showed Open circuit / Closed circuit.
  • END of the Guide.