Philips Lumea Precision Plus SC2003 IPL Hair Removal System - Opening and Battery Replacement

This guide describes opening and replacing the...

iFixit Library Philips Lumea Precision Plus SC2003 IPL Haarentfernungssystem Moderate 15 - 30 minutes Guide 198172
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

This guide describes opening and replacing the replacement battery in the Philips Lumea Precision Plus SC2003. The replacement battery is glued and soldered in place; the existing temperature sensor must be preserved according to the steps described. The exact replacement specifications must be verified before installation.

Step 1

Remove the cap

  • Use a spudger or knife to release and remove the cap in the area of the device's charging port. It is held in place by two clips on the short sides.
Step 2

Opening the housing

  • Release and remove the bottom cover of the device housing by unscrewing two Torx screws.
  • Remove the rear part of the device housing. It is seated very tightly and is held in place by four clips (two on each side) in the indicated areas. Use the appropriate tool to release the clips.
Step 3

Remove and replace the replacement battery

  • The replacement battery is partially glued to the rear housing panel and inside a semi-transparent carrier. Carefully release and remove it. Carefully remove the temperature sensor (overheating protection - thin black cables) from the replacement battery. The connection cables (three in number) must be desoldered from the solder tabs on the replacement battery in order to completely remove the replacement battery.
  • A new replacement battery (see type designation in the photo) can be purchased on some common platforms. Alternatively, you could also make one from two 18650 Li-ion cells with the same specifications (connected in series).
  • In addition to the temperature sensor (overheating protection - thin black cables), which must touch both cells of the replacement battery, there are three connection cables: positive (red, thick), negative (black, thick), and balance (white, thin).
  • Solder the connection cables to the solder tabs of the new replacement battery.
  • Place the temperature sensor between the two cells, apply thermal paste if necessary, and secure it with adhesive tape. The sensor must touch the cells!