Step 1

Repair step

  • After several years of working correctly, the PEAZEFAIR PZEM-061 panel voltmeter broke down overnight, starting to take incorrect measurements: it reads 230 V as 1995V and 99.99A, values that are completely impossible in a home.
Step 2

Repair step

  • View of the display powered at 230 V and view of the housing, with a back cover that is very easy to remove by prying; as soon as it is opened, we can see the main culprit of the failure, the 1 µF yellow capacitor (knowing that this is the one that fails comes from experience gained in other repairs of electronic equipment).
Step 3

Repair step

  • Since the circuit was powered on moments ago, unplug it; PAY CLOSE ATTENTION, to measure the capacitor with a capacitance meter, we must ALWAYS ensure it is 100% discharged and has no voltage, so we will bridge its terminals with scissors, pliers, or a piece of wire; THIS IS BASIC TO AVOID BURNING OUT THE METER.
Step 4

Repair step

  • Tested the 1 uF capacitor and it measures as .274 = 0.274 uF, so it is indeed faulty; this will be a very simple repair.
Step 5

Repair step

  • Since the terminals are visible, replacing the capacitor is much simpler because they can be cut and a replacement capacitor can be soldered on without having to remove the PCB.
Step 6

Repair step

  • View of how the 2 pieces of the terminal remain in order to solder the new replacement to them, making this a minimally invasive and very simple repair.
Step 7

Repair step

  • I'm looking for a replacement in the capacitor box; I have the exact same one since it's a very common replacement part, and it even matches in color: 1 µF / 275V MKP.
Step 8

Repair step

  • The replacement part has been checked, it is correct, it measures practically 1 uF, specifically 0.945 uF.
  • My advice: Never trust a replacement part, even if it is new, if you have the means to measure it, measure it.
Step 9

Repair step

  • Comparison of the broken part with the replacement and trimming of terminals; just out of curiosity, the new one from the same manufacturer and with the same value is slightly larger in size.
Step 10

Repair step

  • With the replacement part positioned in the same place as the old one, I apply the two solder points.
Step 11

Repair step

  • View of the final result.
Step 12

Repair step

  • Before replacing the cover: Test the device; when powered at 241 V, it measures exactly the same as it did before the failure. In this home, the utility company voltage is higher than the 230 V standard.
  • End of the Repair Guide.
  • A very simple repair; a component failure that is very common in many devices. When you find a flat capacitor, either 1 uF 275V, 2.2 uF, or 3.3 uF, always be suspicious of them, as they are usually the cause of many failures that are simple to resolve.