FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

How to Troubleshoot a Samsung Refrigerator That Leaks Water Inside

[youtubevideo|So1Zf-yIj94]Water in the crisper...

iFixit Library Samsung Refrigerator Moderate 2 - 4 hours Guide 207480
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

Water in the crisper drawers and heavy frost or an “ice ball” behind the evaporator cover are often linked in Samsung bottom-freezer refrigerators. This guide shows how to access the evaporator area, install the Samsung drain kit (DA82-01415A), add a secondary defrost heater to prevent the ice ball from returning, and verify operation so the leak and icing don’t come back.

Step 1

Confirm the symptoms and make it safe

  • Look for water collecting in the crisper drawers and ice building on the air ducts or behind the evaporator cover.
  • Plan to address both the drain system and the upper-evaporator icing, because these problems commonly occur together.
  • WARNING: Unplug the refrigerator before removing covers or splicing any electrical wires.
Step 2

Remove the crisper drawer shelf

  • Remove the shelves that block access to the evaporator cover.
  • Press in the two retention tabs at the top of the water filter housing.
  • Pull up on the crisper drawer shelf to remove it.
Step 3

Remove the evaporator cover

  • Use a Phillips screwdriver to remove the four to five screws securing the evaporator cover.
  • Remove any plastic screw covers hiding screws on the metal shelving bracket.
  • Pull the evaporator cover forward, and expect resistance if ice is stuck behind it.
  • Disconnect the two wire clusters on the right side by releasing their small retention clips with a small screwdriver or fingers.
  • Leave the defrost heater wires connected unless you need the extra slack for the heater splice later.
Step 4

Inspect for an ice ball and a stuck fan

  • Check for a large ball of ice near the top of the evaporator area.
  • Check whether ice has seized the evaporator fan, because a stuck fan can stop airflow and worsen icing.
Step 5

Replace the rear drain tubes

  • Use a Phillips screwdriver to remove the eight to 10 screws holding the rear cover panel on the refrigerator.
  • Twist and pull down to remove the old rubber drain tubes.
  • Clean the condenser coils while the rear cover is off.
  • Seat the new drain tubes into the drain pan indentations on the bottom side first.
  • Insert the top of each new drain tube into the plastic housing on the refrigerator.
  • Reinstall the rear cover panel.
Step 6

Remove the metal drain tray

  • Use a flathead screwdriver or a putty knife to slowly work the thin metal drain tray out of its plastic housing.
  • Remove or reposition any long temperature probe in the drain tray so it doesn’t snag and stop the tray from sliding out.
  • Locate the four locking metal tabs on the back of the drain tray that hold it to the evaporator coil housing.
  • Use needle-nose pliers, a flathead screwdriver, or fingers to bend the tabs back toward the rear of the refrigerator to unlock the tray.
  • Separate the drain tray from the evaporator coil housing.
  • The tray has two slots where the locking tabs sit, so use them to guide reattachment during reassembly.
Step 7

Install the drain tray foam strips

  • Dry the drain tray before sticking on the foam-backed foil pieces from the drain kit.
  • Peel off the paper backing to expose the adhesive on each foam strip.
  • Stick the two smaller strips vertically about a third of the way in from each side, roughly centered on the tray.
  • Stick the larger piece starting at the bottom of the tray and working upward, keeping the center drain hole aligned.
  • Reattach the drain tray to the evaporator coil housing, and bend the locking tabs back into place to secure it.
Step 8

Replace the drain thermal probe

  • Use wire cutters to cut and remove the old thermal probe from the defrost heater.
  • Slide the new larger thermal probe onto the defrost heater.
  • Route the metal tip of the probe into the defroster hole.
  • Use needle-nose pliers to crimp the probe’s metal fingers onto the heater so the probe can’t move.
  • The probe alone can reduce leaking, but the video’s permanent approach combines the full drain kit and the added heater.
Step 9

Make room for the heater splice

  • Unplug the defrost heater wire harness to give yourself more room to work in the cabinet.
  • WARNING: Keep the refrigerator unplugged while you splice in the secondary heater.
Step 10

Splice in the secondary defrost heater

  • Insert the refrigerator defrost heater wire into the displacement connector side that allows the whole wire to pass through.
  • Insert the secondary heater wire into the displacement connector side with the closed end.
  • Use slip-joint pliers, or locking pliers if needed, to clamp the connector’s metal blade fully down so it cuts into both wires.
  • Close the blue flap on the connector to help seal it and prevent the connection from backing out.
  • Seal the connector with silicone grease to keep moisture from ruining the connection if the connector isn’t pre-greased.
  • Splicing closer to the refrigerator’s heater harness connector can be quicker than splicing mid-wire.
Step 11

Mount the secondary heater and secure the wiring

  • Use heat-resistant cable ties to mount the heater to the aluminum and copper line at the top of the evaporator area.
  • Contour the heater around the area where the ice ball typically forms, covering most of the copper tube.
  • Trim the excess from the cable ties after the heater is secured.
  • Trim only the gray heater leads if needed, and don’t cut or modify the black heater element.
  • Keep the defrost thermistor (the white part wrapped in black tape) far from both the main heater and the new heater.
  • Add cable ties around the displacement connectors to keep them from opening, and add a tie below the splice as strain relief.
  • Reinsert the wires into the defrost heater wire harness, and bundle excess wire with cable ties so it stays out of the way.
Step 12

Test in forced defrost and troubleshoot the splice

  • Move the evaporator cover aside, keep the fan and thermistor connectors plugged in, and restore power for testing.
  • The source video says forced defrost is safe to run with the evaporator panel moved aside but still plugged in.
  • The procedure to enter forced defrost varies by model and isn’t shown in this source, so use model-specific instructions.
  • In forced defrost, verify the main bottom heater heats strongly and the new upper heater warms the top area.
  • Use these reference temperatures from the video as a check: about 200 °F on the main heater and about 160–170 °F on the added heater.
  • If frosting returns after a few days, recheck the displacement connectors and fully clamp the metal blade down, because a loose clamp can prevent heating.
Step 13

Consider a non-splice alternative if needed

  • Use an alternate approach if you aren’t comfortable splicing wires by applying additional Mylar foam pieces around the copper refrigerant line.
  • The video describes technicians using two drain kits to get extra Mylar pieces for this method.
Step 14

Reinstall the evaporator cover and reassemble

  • Plug in the thermistor and fan connections behind the cover in the top left corner.
  • Plug in the wire harness, because the refrigerator can misbehave if powered without these connections installed.
  • Tuck all wiring fully into the evaporator housing so the cover fits snugly despite the added heater wiring.
  • Reinstall the evaporator cover and its four to five screws.
  • Reinstall the crisper drawer shelf and any other shelves you removed.