FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

How to Use Diagnostic Mode and Forced Defrost on a Maytag Side by Side Refrigerator

[youtubevideo|dFAgjaW_s74]Use this guide to...

iFixit Library Maytag Refrigerator Moderate 20 - 45 minutes Guide 207601
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

Use this guide to enter service diagnostics on a Maytag side-by-side refrigerator (including models MSS25N4MKZ, MSS25C4MGZ, and similar models with a five-button UI) to run tests, check for stored failure indications, and force a defrost cycle when you suspect a defrost problem. Instructions are included for both the in-door ice/water control panel style and the inside-the-door Athena-style control panel used on models without in-door ice and water.

Step 1

Identify your control panel style

  • Confirm the refrigerator has either an external five-button in-door ice and water UI or an inside-the-door Athena-style UI.
  • External five-button UI diagram is [1 Freezer temp] [2 Light] [3 Ice type] [4 Lock] [5 Refrigerator temp].
  • Athena-style UI is inside the fresh-food door area and uses a temperature select/setting button plus the door switch to enter service functions.
Step 2

Prepare the refrigerator for diagnostics

  • WARNING: Unplug the refrigerator before any button-sequence reset to reduce shock risk, and plug it back in only when instructed.
  • Unplug the refrigerator, wait two to three minutes, and plug it back in.
  • Wait 30 to 45 seconds for the refrigerator to boot until the temperature display segments turn back on.
  • Keep the door closed during boot when possible so the controls don’t time out while you’re entering codes.
Step 3

Enter diagnostic mode on the five button in door UI

  • Press the freezer temperature button until it is set to only one blue increment.
  • Press the refrigerator temperature button until it is set to only one blue increment.
  • Press and hold the freezer temperature button and the ice type button at the same time for about five seconds.
  • Release the buttons when every light on the display flashes on.
  • If the lights don’t all flash, reboot again and confirm both temperature bars are set to a single blue increment.
Step 4

Confirm the UI and reset for diagnostic inputs

  • Press all five keys in order from left to right to confirm the buttons and lights work.
  • Wait for all lights to flash again and then turn off to indicate the system is ready for diagnostic commands.
Step 5

Navigate diagnostic steps and read the display

  • Press the light button to advance to a higher diagnostic step number.
  • Press the lock button to go back to a lower diagnostic step number.
  • Press the refrigerator temperature button to toggle the selected test on or off when the step supports manual activation.
  • Use the left-side light segments to identify the current diagnostic step.
  • Use the right-side display to read the test feedback, which indicates whether the step is reporting normal operation or a problem.
  • Some steps run automatically, and many steps briefly turn the lights off between selections.
Step 6

Run forced defrost on the five button in door UI

  • Use the light and lock buttons to navigate to the forced defrost diagnostic step on the control panel.
  • Press the refrigerator temperature button to start forced defrost.
  • Expect the refrigerator to shut off the compressor and all fans while it attempts to run the defrost heater in the freezer cabinet.
  • Caution: The defrost heater area can get hot, so don’t touch freezer panels, wiring, or heater components while the test is active.
  • Press the refrigerator temperature button again to turn the forced defrost step off if the UI supports toggling for that step.
Step 7

Use ice maker tests safely on the five button in door UI

  • Expect the ice maker harvest test to take a significant amount of time, so let it finish its cycle before changing steps.
  • Skip ice maker tests if the water supply is not connected or the ice maker is turned off.
  • Run the ice maker harvest step before running the ice maker water fill step.
  • WARNING: Running the water fill step without performing the harvest step first can cause a double fill and spill water inside the refrigerator.
Step 8

Exit diagnostics on the five button in door UI

  • Unplug the refrigerator and plug it back in to return the unit to normal operation.
  • At the last diagnostic step, pressing the refrigerator temperature button may do nothing, and advancing can loop back to the first diagnostic code.
Step 9

Avoid and clear showroom demo mode on the five button in door UI

  • WARNING: Showroom or demo mode turns cooling off and can make the refrigerator stop cooling until the mode is cleared.
  • Unplug the refrigerator, plug it back in, and wait for it to boot.
  • Within two minutes of booting, press and hold the freezer temperature button and the refrigerator temperature button together for five seconds.
  • Watch for an animation on the display indicating demo mode is active.
  • Clear demo mode by performing the same freezer temp plus refrigerator temp hold again so the refrigerator resumes cooling.
Step 10

Enter service mode on the Athena style UI

  • Locate the Athena-style control panel inside the refrigerator door area.
  • Unplug the refrigerator and plug it back in.
  • Within 30 seconds of powering on, press the temperature select button until only the single light at the top of the control is lit.
  • Press and hold the door switch to simulate the door being closed.
  • Press and hold the temperature setting button for five seconds until all UI lights flash.
  • Wait about 10 seconds for the lights to shut off, which indicates the UI is ready for service selections.
Step 11

Cycle Athena service modes to run compressor or forced defrost

  • Press the temperature setting button to move through service modes, and wait about three seconds after each press.
  • Use the first mode press to force run the refrigerator compressor system.
  • Use the second mode press to turn the compressor off and turn the service lights off.
  • Use the third mode press to turn on the defrost heater for a forced defrost test.
  • Use the fourth mode press to turn the heater off and turn the lights off.
  • Caution: Don’t touch freezer panels or wiring while the heater test is on because components can become hot.
Step 12

Read Athena failure indications and return to normal mode

  • Use the fifth mode press to light the last indicator, even though it doesn’t force a mode.
  • Use the sixth mode press to enter the error code or display fail message mode.
  • Interpret no lights in the error code mode as the refrigerator reporting good working order.
  • Interpret flashing lights in the error code mode as a failure code that the refrigerator believes indicates a problem.
  • An example failure indication is lights D9 and D8 flashing for a refrigerator and defrost sensor error simulation.
  • Press the temperature select button until the UI returns to normal operating mode.
  • The control may show one last light after the error code display before a final press returns it to normal operation.
Step 13

Avoid and clear showroom demo mode on the Athena style UI

  • WARNING: Showroom or demo mode turns cooling off even though the UI looks like it is working.
  • Unplug the refrigerator, wait 15 to 30 seconds, and plug it back in.
  • Within two minutes of booting, press the temperature setting button until the maximum cooling mode is reached.
  • Press and hold the door switch to simulate the door being closed, and press and hold the temperature setting button for about three seconds.
  • Watch for each UI button to flash individually and keep cycling to indicate the demo mode sequence is ready.
  • Press the temperature setting button again to fully engage demo mode.
  • Exit demo mode by repeating the same maximum cooling plus door switch plus three-second hold procedure.