DeLonghi ECAM6900 (PrimaDonna Exclusive) Transmission Nut Replacement

On this series of Delonghi Machine a common...

iFixit Library DeLonghi ECAM Series Moderate 2 hours Guide 211356
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

On this series of Delonghi Machine a common fault is that the infuser assembly gets stuck and does not move. This is due to the infuser being gummed up with excess coffee oils. As it builds up it puts more pressure on the brass carriage nut. Delonghi only sells the entire transmission, this guide aims to help you replace the carriage nut only.

Step 1

Overview

  • A common fault on the delonghi machines is that the infuser piece either doesn't come out properly, or doesnt move into the right position
  • The fault is that the brass transmission nut that sits inside the transmission assembly strips out due to extra force over time.
  • The extra force is caused by excess coffee oils and debris gumming up the infuser mechanism.
Step 2

Safety!

  • Make sure power is disconnected before working on your machine
  • All standard electrical safety rules and guidelines apply. This is a 240V appliance.
Step 3

Infuser

  • The infuser is the piece that you can remove and clean
  • Over time the tube at the bottom doesnt expand well due to coffee oil and debris build up.
  • This needs to be cleaned thoroughly before attempting this repair.
  • In some cases the infuser will need to be fully disassembled and cleaned for best results.
Step 4

Transmission Assembly

  • When this issue happens with the machine, the normal repair is to replace the whole assembly as Delonghi does not sell the transmission nut by itself.
  • The Transmission assembly is part 7313249601 or 7313261451
  • Besides being expensive to replace the whole assembly, its quite wasteful especially when the rest of the assembly is very serviceable.
  • In this guide I will be replacing the brass nut with one I 3D printed using Nylon PA12-CF filament. There are some sellers selling brass models, however there were none in Australia, so I decided to make and sell my own.
  • Nylon PA12 has a lower co-efficient of friction than brass, so should slide easily, and when printed correctly should be well strong enough for small loads in this case.
Step 5

Brass Carriage Nut

  • The video shows the brass carriage nut slipping on the lead screw.
Step 6

Rear Case

  • Remove 2 6G (3.5mm) x 16mm Phillips head Screws from the rear case
  • Slide down and remove
Step 7

Side Panels

  • Remove 4x 6G (3.5mm) x 16mm Phillips head Screws holding the side panels in
  • Side panels not shown in this image
  • Slide towards back of the machine and remove
Step 8

Infuser

  • Remove the Drip Tray and grounds container and open the main door
  • Remove the Infuser by pressing the red toggles
  • If the infuser is stuck, the first step is to put the grounds container & drip tray back in and close the door
  • Power the machine on and hopefully the infuser position will reset
  • If you have the panels open be very careful about powering the machine back on. It is best to slide the side and rear panels back on before powering on again
  • If the infuser still does not get to the right position you can remove the infuser by actuating the lever on the bottom right side of the carriage. This hits a little piece of plastic which moves it to the right side, allowing the infuser to be removed. The infuser removed in the second image to show the lever.
Step 9

Infuser Carriage

  • Remove 2x T25 Screws from the infuser carriage
  • Remove the infuser carriage
Step 10

Transmission Pivot

  • Remove 1x 6G (3.5mm) x 16mm screw with washer for transmission pivot
Step 11

Boiler & Water Pump

  • Remove 2x 6G (3.5mm) x 16mm Phillips Head screws that hold boiler
  • Slide out water pump mounts from plastic recesses
  • Boiler can be moved as much as needed to pull transmission out
Step 12

Hall sensor Cable

  • Remove Hall sensor cable from connector (grey flat cable)
  • Snip any cable ties and move it out of any cable holds.
Step 13

Motor Power

  • Remove the two power wires from the motor control board
Step 14

Transmission

  • The transmission can be carefully shimmied out under the boiler and water pump
  • Pay attention to any snagging wires
  • Dont remove fully there is still two white wires attached to a limit switch.
  • Once those are removed the transmission can be fully removed
Step 15

Hall Sensor

  • Remove 2x 6G (3.5mm) x 10mm Screws for hall sensor board
  • The hall sensor assembly board can be removed
Step 16

Motor

  • Remove the Drive belt
  • Remove the two white wires supplying power from the motor driver board to the brushes. Note the orientation. Its marked but just make sure you know which way they go back
  • Remove the 4x M5x10mm Machine Screws holding the motor to the bracket
Step 17

Bracket

  • Remove the 6x 6G (3.5mm)x13mm Phillips Head screws from the metal bracket
  • The top two screws can be accessed through a hole in the main gear.
Step 18

Transmission Case

  • Remove the 8x 6G (3.5mm) x 16mm Screws holding the transmission case together
  • Split the case open
Step 19

Lead screw nut

  • Remove the M5 locknut from the top of the lead screw
  • Remove the plastic hold down. Take note of the orientation and order of the washers for the bearing.
Step 20

Carriage Nut

  • Put the leadscrew nut back on the end of the leadscrew
  • Using an 8mm socket drive the lead screw until the carriage nut and assembly comes off. If its stripped badly you may need to help it with a screwdriver or manual pressure.
  • You can also turn the white gear by hand
Step 21

Carriage Nut

  • Removal complete!
Step 22

Motor Service

  • While you have everything apart its recommended to check the motor brushes.
  • This step is completely optional
  • To do this you have to bend out the retaining tabs for the brush plate
  • Remove the brush plate and inspect the brushes. Its also recommended to clean the assembly with contact cleaner or similar electrical cleaners.
  • The brushes are 5mmx5mmx 20mm long with a notch and can be removed by bending the brass retaining pin.
  • Once re-assembled, push the metal retaining pieces back in.
  • Put 1 drop of light machine oil in each end of the motor shaft.
Step 23

Lubrication

  • When re-assembling you should clean all surfaces
  • Then apply some Food grade grease. INOX MX6 is a good food safe, PTFE based grease.
  • Apply with an old paint brush
  • Apply to all sliding points and on the lead screw
  • Don't over do it.
Step 24

Re-Assembly Tips

  • Follow instructions 1-20 Backwards to Re-Assemble.
  • Wind the new carriage nut all the way down to the bottom before you put the motor or any other brackets on. Pay attention to the bracket orientation as shown