FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

Guide 1: EURO STIL Professional Hair Dryer, cable issue, intermittent failure.

Attributed iFixit repair guide for Secador Pelo EURO Stil Profesional.

iFixit Library Secador Pelo EURO Stil Profesional Very easy 30 minutes Guide 211361
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Step 1

Repair step

  • Household hair dryer with an intermittent fault: it would work or not depending on how the cord was moved. It has the typical fault of many household appliances: an internal break in one of the wires.
Step 2

Repair step

  • The teardown of the handle is very simple; it has 2 Phillips screws and is fitted into the turbine part.
  • While testing with the hair dryer plugged in, I was able to confirm that the break, which occurs when moving the cable, is, as expected, right at the exit of the protective rubber sleeve.
Step 3

Repair step

  • Interestingly, this manufacturer has placed the power cable, connected to the PCB via soldered terminal blocks; they are not of high quality, as they break when tightened, but they do allow the cable to be changed with basic tools.
  • A very good repairability score for this manufacturer.
Step 4

Repair step

  • With one of the wires from the power strip loose, I try pulling on the brown wire; it's okay. I pull on the blue wire, which stretches like gum and breaks: "classic wear-and-tear breakage, the copper was already broken."
  • It's time to strip the casing back to the point of the break and peel back about 3 cm more.
Step 5

Repair step

  • Once the sheath is stripped, we can see that the copper is cut; we cut both wires to make them even, since the brown one, although not broken, is also damaged.
  • We strip the ends to insert them into the orange terminal block.
Step 6

Repair step

  • Strip about 3 mm off both cables and insert them into the terminal block.
  • Surprise... when applying force, one of the connections on the orange terminal block breaks, so the cable has to be soldered directly to the PCB.
  • Photo 3 is only for illustration of the capacitor model the dryer uses. 47 nF
Step 7

Repair step

  • Given the breakage problem, I am soldering the cable directly to the PCB.
  • When reassembling the device, to facilitate a future teardown and prevent damage to the 2 screw support posts, I apply a drop of petroleum jelly to each post. Blue arrow.
Step 8

Repair step

  • Once assembled, the device works perfectly.
  • I have created a Guide 2, to clean and grease the motor shaft before reassembling the case.
  • End of Guide 1.
  • Other guides in this series: Secador Pelo EURO Stil Profesional