Guide overview

Before you begin

Removing the metal Shield of the Apple display. This shield protects the components from electromagnetic interference.

Step 1

Repair step

  • Lay the display facing down with the stand away from you.
  • Remove the three size 2.0 hex screws on the swing arm and remove the swing arm as well as the plastic shield under it.
Step 2

Repair step

  • Remove the size 2.5 hex screws from each corner that connects the panels to the display and remove them.
Step 3

Repair step

  • Rotate the display so the legs of the display are now facing you
  • Grip the top of the clear panel and lift it upwards, and pull the ADC cable through the hole.
Step 4

Repair step

  • Remove the grey back panel by lifting the bottom and pulling the ADC cable through the hole.
Step 5

Repair step

  • The next layer will be a shiny metal panel, which might have some stickers. Make sure to remove these stickers.
Step 6

Repair step

  • Now locate and remove the lone Phillips screw holding the EMI shield to the display
Step 7

Repair step

  • Now that the screw has been removed, slide the panel towards your body and lift it out.
  • You may need to remove the clear USB port cover to remove the metal EMI shield.