Before you begin

My Husqy broke down on me the other day, the needle instead of moving just made a horrendous whirring sound. Before taking it to the repair shop, I decided to pop it open and see if it was a simple fix that I could take care of quickly and cheaply. Yes to both—a belt had slipped loose—but the disassembly process was a PROCESS, so I thought I’d document it and share it here.

Step 1

Prep

  • First, take out the drawer so you have access to all of the screws.
  • The only tools you’ll need are a screwdriver with torx bits 10 and 20, and probably something to put the screws in to keep track of them. You’ll want a thin screwdriver as some of the wells are narrow.
  • There is a lot of circuitry on the inside of this machine, so take necessary precautions to ground yourself from static discharge.
Step 2

Removing Back Screws

  • Remove the six torx 10 screws on the back represented by the blue squares.
  • Remove the four torx 20 screws represented by the red circles, two on the back and two on the bottom.
Step 3

Remove Back Panel

  • Carefully, but firmly pull the back panel away from the machine.
  • There’s a lip under the knob, while at the opposite end there is a small circuit board and cables, so it’s probably best to pull away from the knob end first. You can easily remove the top cover at this point, too.
  • Take note of which wires are plugged in where. During the process the plug circled in yellow came loose and I had to go back through these photos to find out where to plug it back in.
Step 4

Remove Front Cover

  • Turn the knob to lower the needlebar to its lowest position.
  • Remove the two torx 20 screws, indicated by the red circles.
  • Remove the three torx 10 screws, indicated by the blue squares; two are on the bottom, and the one on top is further back under the cover.
  • Carefully but firmly pull the front cover away from the internal machinery, taking note of wires connecting the various components on the cover to internal ones. The touch screen is part of the cover, so it will come away with it.
  • Note the taut wire in the last photo; some of the wires are very short. You can disconnect them if you need to, but it will impact the functionality of the machine in possibly unexpected ways. I left everything connected.
Step 5

Troubleshooting

  • Take note that even though all of the covers have been removed wires are still connecting them to the internal circuitry. Plan for this restriction on your workspace.
  • With the covers removed it was time to troubleshoot the source of the problem. I used the needle raise/lower button on the front panel to keep the noise repeating as I located the precise physical location of the problem.
Step 6

Belt Repair

  • Thankfully this turned out to be an easy fix: the drive belt had slipped off the knob. I just slipped it back on and the problem was solved.